Lincoln Electric NERTAMATIC 450 Instructions For Use Manual
Lincoln Electric NERTAMATIC 450 Instructions For Use Manual

Lincoln Electric NERTAMATIC 450 Instructions For Use Manual

Ac/dc power source

Advertisement

8695 5522 / G
NERTAMATIC 450 AC/DC POWER SOURCE
EDITION:
EN
REVISION: G
DATE:
05-2018
NERTAMATIC 450 AC/DC
No. W000315023
Instructions for use
8695 5522
REF.:
Original instructions
-1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NERTAMATIC 450 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Lincoln Electric NERTAMATIC 450

  • Page 1 8695 5522 / G NERTAMATIC 450 AC/DC POWER SOURCE No. W000315023 8695 5522 EDITION: Instructions for use REF.: REVISION: G DATE: 05-2018 Original instructions NERTAMATIC 450 AC/DC...
  • Page 2 NERTAMATIC 450 AC/DC POWER SOURCE 8695 5522 / G Thank you very much for the trust you have shown by choosing this piece of equipment. It will give you trouble-enee service if it is used and maintained as recommended. Its design, component specifications and manufacturing are in accordance with applicable European directives.
  • Page 3: Table Of Contents

    NERTAMATIC 450 AC/DC POWER SOURCE 8695 5522 / G CONTENTS A - DESCRIPTION ..........................5 B - INSTALLATION ..........................7 1 - UNPACKING - HANDLING ....................7 2 - CONNECTION ........................9 C - OPERATOR'S MANUAL ......................10 FRONT PANEL CONTROLS ....................10 D - MAINTENANCE ...........................
  • Page 4 NERTAMATIC 450 AC/DC POWER SOURCE 8695 5522 / G REVISIONS REVISION B 07/05 DESIGNATION PAGE Change fuse values REVISION C 06/06 DESIGNATION PAGE To change logos REVISION D 11/08 DESIGNATION PAGE Complete update + spareparts newoffer REVISION E 12/09 DESIGNATION...
  • Page 5: A - Description

    NERTAMATIC 450 AC/DC POWER SOURCE 8695 5522 / G A - DESCRIPTION NERTAMATIC 450 AC/DC...
  • Page 6 The cooling air is taken in through openings in the side panels and the upper front door and then transferred to the rear by means of a fan. NERTAMATIC 450 has several auxiliary power supply systems, which are alternative low- voltage sources that power the cycle box, the AVC, the wire feeding funcion, the BRT, some movements etc.
  • Page 7: B - Installation

    NERTAMATIC 450 AC/DC POWER SOURCE 8695 5522 / G B - INSTALLATION 1 - UNPACKING - HANDLING Operator's protection: Helmet - Gloves - Safety shoes 1) Unpacking 2) Handling  Cut the box straps. You can now install the power supply either : ...
  • Page 8 NERTAMATIC 450 AC/DC POWER SOURCE 8695 5522 / G 3) Location of the current source (power source): For optimised operation and a longer life, the power source location should be selected carefully. The device should not be installed in places exposed to humidity, high temperature or corrosive fumes.
  • Page 9: Connection

    NERTAMATIC 450 AC/DC POWER SOURCE 8695 5522 / G 2 - CONNECTION The installation is wired for a 400V mains voltage. If the power supply voltage is 230V, 415V or 440V, the transformers inside the power source must be rewired accordingly.
  • Page 10: C - Operator's Manual

    NERTAMATIC 450 AC/DC POWER SOURCE 8695 5522 / G C - OPERATOR'S MANUAL FRONT PANEL CONTROLS WHITE indicator POWER ON BLACK button RED button GREEN indicator IN SERVICE RED indicator FAULT NERTAMATIC 450 AC/DC...
  • Page 11: D - Maintenance

    NERTAMATIC 450 AC/DC POWER SOURCE 8695 5522 / G D - MAINTENANCE 1 - SERVICING  So that the machine continues to provide good service for as long as possible, a certain minimum of care and maintenance is necessary  The frequency of this maintenance work is given on the basis of the production of one work station per day.
  • Page 12: Troubleshooting

    NERTAMATIC 450 AC/DC POWER SOURCE 8695 5522 / G 2 - TROUBLESHOOTING CHOPPER CONTROL BOARD NERTAMATIC 450 AC/DC...
  • Page 13 NERTAMATIC 450 AC/DC POWER SOURCE 8695 5522 / G Signs Item Causes Remedies Chopper control board If off: board power supply Call the After Sales Service dept. failed Chopper control board If off: board power supply Call the After Sales Service dept.
  • Page 14 NERTAMATIC 450 AC/DC POWER SOURCE 8695 5522 / G AUXILIARY SOURCE BOARD NERTAMATIC 450 AC/DC...
  • Page 15 NERTAMATIC 450 AC/DC POWER SOURCE 8695 5522 / G Display during operation LEDS VERTES GREEN LEDs ON/OFF Allumée : Hacheur Actif Chopper ON Eteinte : OFF: Hacheur Eteint Chopper OFF ON : Allumée : Présence Pilot Current Courant Pilote OFF:...
  • Page 16 NERTAMATIC 450 AC/DC POWER SOURCE 8695 5522 / G AC MODULE CONTROL BOARD (OPTIONAL) NERTAMATIC 450 AC/DC...
  • Page 17 NERTAMATIC 450 AC/DC POWER SOURCE 8695 5522 / G Signs Item Causes Remedies Ac module control source +15V_0 If LED off: board power Call the After Sales Service dept. board. supply failed AC module control source +15V_1 If LED off: board power Call the After Sales Service dept.
  • Page 18: Spare Parts

    NERTAMATIC 450 AC/DC POWER SOURCE 8695 5522 / G 3 - SPARE PARTS  In order to avoid errors when supplying spare parts, we recommend that you send us a copy of the page with the list of parts duly completed. Please specify in the Order column the number of parts desired and indicate the type and the serial number of your equipment.
  • Page 19 NERTAMATIC 450 AC/DC POWER SOURCE 8695 5522 / G  normally in stock  not in stock on request Order Item Ref. Stock Designation  POWER CIRCUIT   W000147271 Rectifier   W000140151 Chopper   W000148781 Capacitor unit for chopper ...
  • Page 20 NERTAMATIC 450 AC/DC POWER SOURCE 8695 5522 / G  normally in stock  not in stock on request Order Item Ref. Stock Designation  POWER CIRCUIT   W000147114 Line contactor   W000147169 Mains filter   W000352128 Current sensor ...
  • Page 21 NERTAMATIC 450 AC/DC POWER SOURCE 8695 5522 / G  normally in stock  not in stock on request Order Item Ref. Stock Designation  CONNECTION   W000370189 Power terminal assembly  POWER CIRCUIT  W000137850 Fuse holder 10*38 ...
  • Page 22: Personal Notes

    NERTAMATIC 450 AC/DC POWER SOURCE 8695 5522 / G PERSONAL NOTES Lincoln Electric France S.A.S. Avenue Franklin Roosevelt 76120 Le Grand Quevilly 76121 Le Grand Quevilly cedex www.lincolnelectriceurope.com NERTAMATIC 450 AC/DC...

This manual is also suitable for:

W000315023

Table of Contents