Configuration
7.1.5

Enable / Disable PIN

7.1.6

Factory Reset

7.2

Configuration via PC

18
Security Products
When admin password is enabled, the access to the configuration menu is denied
and only accessible by entering the correct PIN. Furthermore remote servicing is
not possible under that condition (see Chapter 7.2). Configuration can be displayed
but not changed.
The user password blocks the normal operation mode. Only after entering the PIN
keyboard and joystick are accessable. With the key combination Shift + both joy-
stick buttons the HMI device can be blocked at any time.
Follow these steps to activate a PIN:
Choose the desired menu item in the configuration menu and enter a number
consisting of 4 digits (but not „0000"). After saving (menu item save changes) this
PIN is active.
Follow these steps to deactivate a PIN:
Choose the desired menu item in the configuration menu and enter „0000" (four ti-
mes zero) After saving (menu item save changes) access is possible without a
PIN.
Important: PIN input is only possible when the numeral block matches one of the two keyboard
layouts from Chapter 11.2.
Unsaved configured values and PINs are discarded when leaving the configuration menu. In this case
the last configuration and PIN remains valid.
Follow these steps to restore factory settings under menu item factory defaults:
Open the configuration menu and navigate to the menu item factory defaults by
moving the joystick forward / backward.
When the desired menu item is displayed, move the joystick right to restore the
factory settings.
Return to the configuration menu by moving the joystick leftward.
To save the configuration navigate to the menu item save changes and perform
the saving by moving the joystick rightward.
After saving the configuration menu will be left automatically.
In case changes are not supposed to be saved select the menu item abort
changes and confirm with a rightward joystick movement or leave the configura-
tion menu with the keystroke combination from chapter 7.1.1.
Alternatively to the implemented configuration menu the SUT50 can be configured
from a PC via LAN-Interface. Therefore the program VmnetCfg2.exe is required,
which must be executed on a Windows®-PC.
Configuration via LAN requires furthermore that the IPs of the PC and the SUT50
are in the same network segment. Since that is most often not the case it is
adviseable to configure the IP address of the SUT50 with the implemented configu-
ration menu first.