Emerson PACMotion IC830DP00306 Installation And User Manual page 99

Psd
Table of Contents

Advertisement

PACMotion™ PSD Installation and User Manual
GFK-3168A
Rotary Switch Setting
00
01 to 99
The PC subnet mask must be set to 255.255.255.0 or 255.255.255.128 When connecting the PSD
directly to a PC, use static IP addressing (not 00).
5.18.4.1
Static IP addressing
When connecting the drive directly to a PC, static IP addressing must be used. Set rotary switches
S1 and S2 to a number different from 00 (see table above).
5.18.4.2
Dynamic IP addressing (DHCP and Auto-IP)
With S1 and S2 both set to 0, the drive is in DHCP mode. The drive will acquire its IP address from an
external DHCP server if present in the network. If a DHCP server is not present, the drive will assume
an Automatic Private IP Address of the form 169.254.x.x.
If your PC is directly connected to the drive, and set to obtain an IP address automatically in the
TCP/IP settings, a connection will be established with both devices using compatible automatically
generated addresses. It can take up to 60 seconds for a PC to configure an Automatic Private IP
Address (169.254.x.x).
5.18.4.3
Changing the IP address
If the switches are altered while 24 V Logic power is supplied to the drive, you must switch off and
then switch on again the 24 V supply voltage. This action will reset the address.
5.18.4.4
IP address mode
By default, the drive utilizes the method described above to acquire its IP address. A method of
setting the IP address independent of the Rotary switches is available. More information is available
in the PACMotion Workbench Online Help or in the Settings Screen-> Fieldbus-> TCP/IP screen in
PACMotion Workbench.
Mechanical Installation
Drive IP Address
DHCP/AutoIP address. The IP address of the drive is obtained
from the DHCP server on your network. If no DHCP server is
found the IP addresses is an AutoIP address (it is internally gen-
erated following the AutoIP protocol and will be of the form
169.254.xx.xx).
Static IP Address. The IP address is 192.168.0.nn, where nn is the
number from the rotary switch. This setting generates addresses
in a range from 192.168.0.1to 192.168.0.99. Example:if S1 is set
to 2 and S2 is set to 5 – the IP address is 192.168.0.25
Section 5