Motor connector X2 with shielding connection
Figure 30: Motor Connector X2 with Shielding Connection
Alternative connection for the motor power connection by mating connector with strain relief.
Strip the external cable sheath to a length of approx. 120 mm, taking care not to damage the
braided shield. Push the braided shield (1) back over the cable and secure with a rubber sleeve (2)
or shrink sleeve.
Shorten all the wires apart from the protective earth (PE) wire (green/yellow) by about 20 mm so
that the PE wire is now the longest wire. Strip all wires and fit wire end ferrules.
Secure the braided shield of the cable to the shroud with a cable tie (3) and use a second tie (4) to
fasten the cable.
Wire the connector as shown in the connection diagram. Plug in the connector to the socket on the
front of the PSD.
Screw the connector in place. This ensures that there is conductive contact over a large surface area
between the braided shield and the front panel.