2RB/2RC/2RD/2RF/3R6
21. Detach seven connectors (b) and (c) from the con
nector of the container relay PWB (a).
Figure 4-210
22. Detach one screw (b)(M3x8).
23. Release three lock sections (c) by using the flat
head screwdriver (d).
24. After lifting the high voltage PWB assembly (a) in
the direction of the arrow from the main unit (e),
remove it.
Figure 4-211
4-110
^