Kyocera ECOSYS P5026cdw Service Manual page 117

Pf-5110 paper feeder
Hide thumbs Also See for ECOSYS P5026cdw:
Table of Contents

Advertisement

2RB/2RC/2RD/2RF/3R6
14. Remove the primary transfer unit (a) in the upper
direction from the process unit frame (b).
IMPORTANT
Take care not to hold the transfer belt when pulling, put
on a flat place.
Figure 4-44
15. Remove FFC (a) of the drum unit from the connec ­
tor (b) of the unit relay PWB.
16. Release two lock levers (c) and (d) of the drum unit.
17. Remove the drum unit (e) in the direction of the
arrow from the process frame (f).
18. In a similar way remove each color of the drum unit.
IMPORTANT
When removing the drum unit, take care not to touch the
drum.
Figure 4-45
4-24