2RB/2RC/2RD/2RF/3R6
*1
Up to upper limit height line in the cassette.
Item
Description
26 ppm model
21 ppm model
Transfer system
Primary: Transfer belt method
Secondary: Transfer roller method
Separation system
Diameter separation, separation needle
Cleaning
system
Drum
Counter blade
Primary trans
fer
Counter blade
Charge erasing system
Exposure by cleaning lamp (LED)
Fusing system
Heat and pressure fusing with the heat roller and the press
roller
Heat source: halogen heater
Abnormally high temperature protection devices: thermostat
Memory
512 MB
Interface
USB Interface Connector: 1 (Hi
Network interface: 1
(10 BASE-T/100 BASE-TX/100
USB Port: 1 (Hi-Speed USB)
Wireless LAN support
(ECOSYS P5026cdw only)
-Speed USB)
0 BASE-T)
Wireless LAN support
(ECOSYS P5021cdw only)
Operating
Environment
Temperature
10 to 32.5°C/50 to 90.5T
Humidity
10 to 80%
Altitude
3,500 m/11 ,482 ft maximum
Brightness
1,500 lux maximum
Dimension (W x D x H)
16.42" x 16.89" x 19.49" /410 x 410 x 329 mm
Weight
(without toner container) Approx. 46.3 Ib/Approx. 21 kg
Space Required (W x D)
(Using multi purpose tray) 16.15" x 23.39"/410 x 594 mm
Power Source
120 V Specification Model: 120 V 60 Hz 8.6 A
230 V Specification Model: 220 to 240 V 50 Hz 4.5 A