4. White Balance Adjustment (VC-245 board)
Correct the white balance.
If deviated, the reproduction of the EVF screen may degenerate.
Mode
Camera
Subject
Arbitrary
Measurement Point
Check on EVF screen
Measuring Instrument
Adjustment Page
D
Adjustment Address
97, 98
Specified Value
The EVF screen should not be
colored.
Note1: Check the white balance only when replacing the following parts.
If necessary, adjust them.
1. LCD panel
2. Light induction plate
3. IC1802
Note2: Use the AC power adaptor.
Adjusting method:
Order Page Address Data
1
0
01
01
2
D
97
80
3
D
98
80
4
D
98
5
D
97
6
D
97
7
D
98
8
D
98
9
D
98
10
0
01
00
Procedure
Set the data.
Set the data, and press PAUSE
button.
Set the data, and press PAUSE
button.
Check that the EVF screen is not
colored. If not colored, proceed
to step 10.
Change the data so that the EVF
screen is not colored.
Press PAUSE button.
Change the data so that the EVF
screen is not colored.
Press PAUSE button.
If the EVF screen is colored,
repeat steps 5 to 9.
Set the data.
5-30