4-3. APC & AEQ Adjustment (VC-245 Board)
Mode
Playback
Signal
Recorded signal at "Preparations
before adjustments"
Measurement Point
Pin w; of CN004 (RF MON) (Note 1)
Ext. trigger: Pin qj of CN004 (SWP)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
18, 19, 1B, 1C, 21, 2C
Specified Value
The data of page: 3, address: 03 is
"00"
Note 1: Connect a 75Ω resistor between Pin w; and Pin ql (GND) of
CN004.
75Ω resistor (Parts code: 1-247-804-11)
Note 2: The "AGC Center Level Adjustment" must have already been
completed before starting this adjustment.
Adjusting method:
Order Page Address Data
1
2
0
01
01
3
3
33
08
4
5
3
01
07
6
3
02
7
3
03
8
Note3: If the data is other than "00", adjustment has errors. Take an
appropriate remedial measures according to the errors referring to
the following table.
Data
Contents of defect
20
Perform re-adjustment. (Note 4)
30
The machine is defective
50
Perform re-adjustment. (Note 4)
60
The machine is defective
80
The machine is defective
Note 4: If this data is displayed twice successively, the machine is defective.
PB RF signal is stable
Pin w;
Pin qj
Procedure
Playback the recorded signal at
"Preparations before
adjustments"
Set the data.
Set the data.
Confirm that the playback RF
signal is stable. (Fig. 5-3-6.)
Set the data, and press PAUSE
button.
Check that the data changes
from "07" to "00" in about 20
seconds after pressing PAUSE
button.
Check that the data is "00".
(Note3)
Perform "Processing after
Completing Adjustments".
6.7 msec
Fig. 5-3-6.

4-4. Processing after Completing Adjustments

Order Page Address Data
1
2
30
2
3
33
3
0
01
5-45
Procedure
00
Set the data.
00
Set the data.
00
Set the data.

Hide quick links: