• ENCODER Ca BIST Check
Order Page Address Data
1
3
10
8D
2
3
12
10
3
3
12
00
4
3
13
04
5
3
14
6
3
15
7
3
• ENCODER Cb BIST Check
Order Page Address Data
1
3
10
8E
2
3
12
10
3
3
12
00
4
3
13
04
5
3
14
6
3
15
7
3
Procedure
Set the data, and press PAUSE
button.
Set the data, and press PAUSE
button.
Set the data, and press PAUSE
button.
Set the data, and press PAUSE
button.
Check that the data is equal to
either of the following values.
And memorize the case number
of the value.
NTSC model:
11 (Case1), 4E (Case2)
PAL model:
E8 (Case1), 7B (Case2)
Check that the data is equal to
the following value which case
number is equal to that of
address 14.
NTSC model:
FD (Case1), 3B (Case2)
PAL model:
62 (Case1), B0 (Case2)
If the data of address 14 and
address 15 are correct, IC301
ENCODER Ca playback system
is normal.
Procedure
Set the data, and press PAUSE
button.
Set the data, and press PAUSE
button.
Set the data, and press PAUSE
button.
Set the data, and press PAUSE
button.
Check that the data is equal to
either of the following values.
And memorize the case number
of the value.
NTSC model:
5C (Case1), BC (Case2)
PAL model:
96 (Case1), 35 (Case2)
Check that the data is equal to
the following value which case
number is equal to that of
address 14.
NTSC model:
20 (Case1), A8 (Case2)
PAL model:
79 (Case1), 7C (Case2)
If the data of address 14 and
address 15 are correct, IC301
ENCODER Cb playback system
is normal.
1-6. Processing after Completing Playback System
Check
Order Page Address Data
1
0
01
2
C
42
3
8
21
4
0
01
5
5-51
Procedure
01
Set the data.
Set the following data, and press
PAUSE button.
00: DCR-PC4E
28: DCR-PC5/PC5E
03
Set the data, and press PAUSE
button.
00
Set the data.
Turn off the power and turn on
again.