4.2 Reinforced DC link busbars

Detaching the pre-assembled power cable from the motor connector
If the power cable needs to be routed through a confined space, the motor connector must
be detached from the preassembled cable.
Preassembled power cable with push-in connect-
or
Note
Screwdrivers with an insulated shaft are not suitable because it will not be possible to insert
them deep enough into the terminal.
4.2
Reinforced DC link busbars
4.2.1

Description

Reinforced DC link busbars are available for 50 mm and 100 mm wide components in
booksize format. They are used to increase the current carrying capacity of the components
used to conduct the DC link current from 100 A to 150 A.
Reinforced DC link busbar for 50 mm
wide components
Type no.: 6SL3162-2DB00-0AA.
80
To remove, insert a 0.6 x 3.5 slot-head screw-
driver into the opening provided above the termi-
nal location and withdraw the conductor.
Reinforced DC link busbar for 100 mm wide components
Type no.: 6SL3162-2DD00-0AA.
Power Units in Booksize C/D-Type Format