Now insert coding keys into the matching slots on the motor connector terminal. In order to prevent the connector with
②
coding key
from being inserted into the left-hand connector terminal, a coding key must be inserted into the matching
③
slot
of this terminal. Insert a coding key into the uppermost slot
The connector with coding key
connector and terminal with coding keys
4.1.5.4
Pre-assembled power cables
Description
The pin assignments of the pre-assembled power cables are as follows:
Cable
Phase U2
Phase V2
Phase W2
Protective conductor connection (PE)
Holding brake BR+
Holding brake BR-
Power Units in Booksize C/D-Type Format
Manual, 01/2017, 6SL3097-4AC20-0BP1
①
is now only compatible with the terminal with coding key
②
④
and
.
④
of the right-hand connector terminal.
③
Color
Black
Black
Black
Green/yellow
Black
White
Accessories
4.1 Motor connector
. The same applies to the
Labeling
U/L1
V/L2
W/L3
-
-
-
79