Accessories
4.1 Motor connector
4.1.2.2

Screw connection

Connector with screw connection
When crimped, conductor end sleeves must not exceed the maximum dimensions of 3.6 x 3.2 mm.
1)
Only use prefabricated MOTION-CONNECT power cables.
2)
4.1.2.3

Crimping conductor end sleeves

The following crimping tool is available from Weidmüller to crimp conductor end sleeves
(www.weidmueller.com).
● Type PZ 6/5 Article No. 9011460000
Figure 4-1
Note
Crimping 6 mm
When the 6 mm
crimped, it must be ensured that the outer dimension of the crimped end sleeve specified
above is not exceeded, as otherwise the individual conductors will not fit into the terminals.
70
1.5 mm
2.5 mm
2
2
AWG 16
AWG 14
✓ 2x
✓ 2x
Crimp shape PZ 6/5
conductor end sleeves (AWG 10)
2
conductor end sleeves (AWG 10) for the phase and PE conductors are
2
4 mm
6 mm
10 mm
2
2
AWG 12
AWG 10
AWG 8
1)
1)
✓ 2x
Not pos-
Not pos-
sible
sible