Electrical Connection - Siemens Sinamics S120 Manual

Power units, booksize c/d type format
Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Accessories
4.1 Motor connector
Note
Same connector types for Double Motor Modules
Two connectors of identical type must be used on Double Motor Modules. It will not
otherwise be possible to plug them into the module.
Note
Function warranty
The motor connection plugs 6SL3162-2M.00-0AC0 as well as the motor connection plugs
used in the MOTION-CONNECT cable assemblies have been type-tested in combination
with the Motor Modules. Compliance with the stipulations made in the EC Declaration of
Conformity is only ensured in combination with these motor connection plugs.
The cULus approval has been granted for the motor connection plug system 6SL3162-
2M.00-0AC0 as well as the motor connection plugs used in the MOTION-CONNECT cable
assemblies. Warranty for the technical function can only be ensured in combination with the
stated motor connection plugs.
4.1.2

Electrical connection

The terminal assignments for individual cores at the motor connector are shown in the
following diagram.
Connections for connector with push-in terminals
68
Catch
Holding brake connection BR+ (black)
Holding brake connection BR- (white)
Motor protective conductor connection (PE)
Phase contact U, V, W
Locking lever (for push-in connector only)
Connections for connector with screw terminals
Power Units in Booksize C/D-Type Format
Manual, 01/2017, 6SL3097-4AC20-0BP1

Advertisement

Table of Contents
loading

Table of Contents