9.4

Work for clearing faults

9.4.1 Moving the control piston into the end position

1.
Make sure that the compressed air supply is switched off.
2.
Reduce the fluid pressure by activating the extraction point.
Fig. 15: Auxiliary actuator
3.
NOTICE!
If the auxiliary control is actuated in a pressurised state, there is a risk of
destroying the valve!
Press in the auxiliary control ( Fig. 15/1).
The control piston is pushed into the end position.
ð
4.
Perform test run (
GB–40
Operating instructions
Ä Chapter 7.3 'Start-up' on page 29).
T-Dok-236-GB-Rev.1