Clean The Diaphragm Pump - Krautzberger MP-400 Operating Instructions Manual

Diaphragm pump
Table of Contents

Advertisement

Diaphragm pump MP-400
8.4

Clean the diaphragm pump

WARNING!
Risk of injury due to improper cleaning!
Detergents may be harmful to one's health and be easily flammable. Furthermore, seals of the
diaphragm pump can be destroyed.
Note:
Adhere to the safety data sheets of the cleaning product manufacturer.
Do not fully immerse the diaphragm pump in a cleaning product.
Do not use any high-pressure cleaning devices.
1.
Interrupt the compressed air supply in a suitable location (e.g. shut-off device).
2.
Dip the fluid intake hose into a suitable detergent.
3.
Switch on the compressed air supply.
4.
Rinse out the diaphragm pump by activating the extraction point until only detergent liquid
escapes.
5.
Disrupt the compressed air supply and secure it against restart.
6.
Activate the extraction point again to depressurize the diaphragm pump.
7.
Leave detergent liquid in the diaphragm pump.
8.
Clean the outside of the device with a cloth dipped in cleaning solution.
Article No. 200-0102
ENGLISH