General Information About The Start-Up - Krautzberger MP-400 Operating Instructions Manual

Diaphragm pump
Table of Contents

Advertisement

WARNING!
Hearing damage due to excessive noise exposure!
Depending on the operating conditions, the sound pressure of the device/machine may cause
hearing damage.
Note:
Take suitable action to reduce the impact of the existing sound pressure level. The owner
is responsible for the type and implementation of suitable measures, which may depend
on the local conditions.
WARNING!
Risk of fatal injury, risk of injury or property damage due to damaged or disconnected
lines!
Damaged or disconnected lines can cause death, serious injuries or property damage due to
whip-like movements and the spraying of fluids.
Note:
Check the fluid and compressed air lines for damage and a tight fit prior to every work
process.
7.2

General information about the start-up

Adhere to the following general information for the start-up:
n
Carry out the start-up of the diaphragm pump only in compliance to the steps described in this
operating manual.
n
Always observe the applicable country-specific safety, accident prevention, occupational
safety, and environmental protection regulations for the area of use for the diaphragm pump.
n
Check the material and compressed air hose lines for damage and tight fit before each use.
n
The chemical consistency of the materials used by us cannot always be reliably assessed due
to the large variety of utilised fluids, concentrations, temperatures, and impurities. For this
reason, please test the suitability because we cannot extend any respective guarantees.
n
Adhere to the spray media manufacturer's safety data sheets.
n
Only operate the diaphragm pump in compliance with the values specified in (
'Technical data' on page 52).
n
Only operate the diaphragm pump after fastening it properly to a suitable supporting structure.
n
Do not hold the diaphragm pump in your hand during operation.
n
It is recommended to flush the diaphragm pump prior to initial start-up using a suitable
cleaning agent.
n
Make sure that the connected compressed air is oil-free and free of solid matter.
GB–28
Operating instructions
T-Dok-236-GB-Rev.1
Ä Chapter 12
mail@krautzberger.com, www.krautzberger.com