Continuous Dispensing Timer (S1 Dip Switch 5 & 6); Bin Control Selector (S1 Dip Switch 7) - Hoshizaki DCM-300BAH Service Manual

Hide thumbs Also See for DCM-300BAH:
Table of Contents

Advertisement

4. Continuous Dispensing Timer (S1 dip switch 5 & 6)
The dispense mode switch must be in the "CONTINUOUS" position for this setting to
apply. The factory setting allows ice to be dispensed continuously for 20 sec. on push
button models and for a maximum of 60-sec. on Opti-Serve models.
NOTICE! On Opti-Serve models, do not adjust S1 dip switch 5 & 6 out of the factory
default position.
Note: The ice dispense solenoid has an internal overload protector. When set to "No
Limit" the internal protector may open if ice dispense solenoid is energized longer than
3 to 4 min. at one time.

5. Bin Control Selector (S1 dip switch 7)

The appliance is factory set with mechanical bin control operation. No adjustment is
required. In the factory default position (S1 dip switch 7 in the off position), the gear motor
delay after the upper float switch closes is 5 seconds. WARNING! Do not adjust S1
dip switch 7 out of the factory default position. This dip switch must be left in the
factory default position or the appliance will not operate correctly.
S1 Dip Switch Setting
No. 7
OFF
ON
S1 Dip Switch Setting
No. 5
No. 6
OFF
OFF
ON
OFF
OFF
ON
ON
ON
Bin Control Application
Bin Control (Mechanical)
Bin Control (Infrared Sensor) with optional
Mechanical Bin Control Backup
39
Dispense Time
No Limit
20 Seconds
60 Seconds
No Limit
Gear Motor Delay
5 seconds
30 seconds