6. Bin Control Shutdown Delay, Agitation, and Ice Purge Timer (S1 dip switch 8)

Only available when S1 dip switch 7 is in the "OFF" position. Factory set for normal
operation. No adjustment is required. The shutdown delay is the time between the bin
control proximity switch opening and the control board shutting down the appliance or
starting the S1 dip switch 9 bin control shutdown timer (2A8054-01 and 2A9093-01 only).
E-0 (H) and Later: A 2-second periodic agitation was added to occur every 90 minutes.
WARNING! Do not adjust S1 dip switch 8 out of the factory default position. This
dip switch must be left in the factory default position or the appliance will not
operate correctly.
Bin Control Shutdown Delay
S1 Dip
2A4296-01 CB Only
Switch
(See Dip switch 9 for
Setting
2A8054-01 and 2A9093-01 CB)
2A4296-01
E-0 (G) and Earlier
No. 8
2A8054-01 and
2A9093-01
OFF
0.25 sec.
ON

7. Bin Control Shutdown Delay (S1 dip switch 9)

2A8054-01 and 2A9093-01 Only. Only available when S1 dip switch 7 is in the "OFF"
position. Factory set for optimum performance. Do not adjust. Dip switch 9 shutdown
timing starts when Dip Switch 8 Bin Control Shutdown Delay timer terminates.
The shutdown delay is the time between the bin control proximity switch opening and the
control board shutting down the appliance. WARNING! Do not adjust S1 dip switch 9
out of the factory default position. This dip switch must be left in the factory default
position or the appliance will not operate correctly.

8. Factory Use (S1 Dip Switch 10)

Factory set for proper operation. Do not adjust. This must be left in the factory default
position.
2A4296-01
E-0 (H) and Later
90-60 Second
Sequence
(150-sec. total)
6 to 10 sec.
S1 Dip Switch
Setting
No. 9
OFF
ON
Storage Bin Periodic Agitation
2A4296-01
2A4296-01
E-0 (H) and Later
E-0 (G) and
2A8054-01 and
Earlier
2A9093-01
No Agitation
2 Seconds
No Agitation
Bin Control Shutdown Delay
90-60 Second Sequence
(150 sec. total)
6 to 10 Seconds
40
Ice Purge Timer
2A4296-01
2A8054-01
2A9093-01
60 Seconds
(1 min.)
300 Seconds
(5 min.)