4. Continuous Dispensing Timer (S1 dip switch 5 & 6)
The factory setting allows ice to be dispensed continuously for 20 sec. The DCM-270BAH
may be adjusted to other dispense time options.
NOTICE! On DCM-270BAH-OS, do not adjust S1 dip switch 5 & 6 out of the factory
default position.
Note: The ice dispense solenoid has an internal overload protector. When set to "No Limit"
the internal protector may open if ice dispense solenoid is energized longer than 3 to 4
min. at one time.

5. Bin Control Selector (S1 dip switch 7)

The bin control is factory set. No adjustment is required. WARNING! Do not place
S1 dip switch 7 in the "ON" position. This dip switch must be left in the factory
default position or the appliance will not operate correctly.
S1 Dip Switch Setting
No. 7
OFF
ON

6. Bin Control Shutdown Initiation Delay (S1 dip switch 8)

Only available when S1 dip switch 7 is in the "OFF" position. Factory set for normal
operation. No adjustment is required. The shutdown delay is the time between the bin
control micro-switch opening and the control board shutting down the appliance or
starting the S1 dip switch 9 bin control shutdown timer (2A8084-01 and 2A9093-01 only).
E-0 (H) and Later: A 2-second periodic agitation was added to occur every 90 minutes.
WARNING! Do not adjust S1 dip switch 8 out of the factory default position. This dip
switch must be left in the factory default position or the appliance will not operate
correctly.
S1 Dip
Switch
Bin Control Shutdown Delay
Setting
2A4296-01
E-0 (G) and Earlier
No. 8
2A8084-01 and
2A9093-01
OFF
0.25 sec.
ON
S1 Dip Switch Setting
No. 5
No. 6
OFF
OFF
ON
OFF
OFF
ON
Bin Control Application
Bin Control (mechanical stand-alone)
Bin Control (Infrared Sensor) Stand-Alone and
with optional Mechanical Bin Control Backup
2A4296-01
E-0 (H) and Later
90-60 Second
Sequence
(150 sec. total)
6 to 10 sec.
Dispense Time
No Limit
20 Seconds
ON
60 Seconds
ON
No Limit
Storage Bin Periodic Agitation
2A4296-01 E-0 (G)
and Earlier
Later, 2A8084-01
and 2A9093-01
No Agitation
No Agitation
35
Gear Motor Delay
5 seconds
30 seconds
Ice Purge Timer
2A4296-01
2A4296-01
E-0 (H) and
2A8084-01
2A9093-01
60 Seconds
2 Seconds
(1 min.)
300 Seconds
(5 min.)