Specification Sheet
AC SUPPLY VOLTAGE
COMPRESSOR
GEAR MOTOR
AGITATING MOTOR
DISPENSING MOTOR
OTHER
MAXIMUM FUSE SIZE
MAX. HACR BREAKER (USA ONLY)
MAX. CIRC. BREAKER (CANADA ONLY)
MINIMUM CIRCUIT AMPACITY
ELECTRIC & WATER CONSUMPTION
ELECTRIC
W (kWH/100 lb.)
POTABLE WATER
WATER-COOLED CONDENSER
gal./24HR (gal./100 lb.)
BIN CONTROL SYSTEM
REFRIGERANT CHARGE
Performance Data Sheet
APPROXIMATE ICE PRODUCTION
PER 24 HR.
lb./day kg/day
APPROXIMATE ELECTRIC
CONSUMPTION
watts
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
gal./day l/day
EVAPORATOR OUTLET TEMP.
°F °C
HEAD PRESSURE
PSIG kg/cm²G
SUCTION PRESSURE
PSIG kg/cm²G
WATER FLOW FOR CONDENSER
PRESSURE DROP OF COOLING WATER LINE
HEAT OF REJECTION FROM CONDENSER
HEAT OF REJECTION FROM COMPRESSOR
115/60/1
115 V
7.8 RLA
115 V
2.4 FLA
115 V
0.9 FLA
115 V
0.9 FLA
120 V
0.6 A
20 A
20 A
20 A
20 A
90/70°F
70/50°F
966 (4.48)
940 (3.70)
61 (12.0)
71 (12.0)
485 (112)
299 (49)
Mechanical Bin Control (Proximity Sw.)
R-404A, 11.5 oz. (325 g)
Ambient
Temp. (°F)
50
70
590
80
549
90
517
100
488
70
940
80
951
90
963
100
964
70
370
1.40
80
409
1.55
90
422
1.60
100
578
2.19
12
70
80
12
90
13
100
15
70
255
17.9
80
255
17.9
90
255
17.9
100
261
18.3
70
36
80
37
90
38
100
40
20 gal/h (AT 90°F /WT 70°F)
Less than 7 PSIG
6,000 BTU/h (AT 90°F /WT 70°F)
900 BTU/h (AT 90°F /WT 70°F)
60
54.5 LRA
1/4 HP
55 W
55 W
Water Temp. (°F)
70
268
571
259
249
538
244
512
232
235
221
478
217
--
944
--
--
955
--
966
--
--
962
--
--
422
1.60
490
1.85
546
2.07
621
2.35
-11
12
-11
-11
13
-11
-11
13
-11
-10
15
-10
255
17.9
255
17.9
255
17.9
261
18.3
2.5
36
2.5
2.6
37
2.6
38
2.7
2.7
2.8
40
2.8
90
560
254
528
239
497
226
442
201
948
--
959
--
965
--
961
--
677
2.56
848
3.21
867
3.28
1161
4.40
12
-11
13
-11
15
-10
15
-10
255
17.9
255
17.9
255
17.9
261
18.3
36
2.5
37
2.6
38
2.7
40
2.8
ENG F-013.0.1196