Bc (Infrared Sensor) Shutdown Delay (S1 Dip Switch 1, 2, 3); Drain Frequency Control (S1 Dip Switch 4); Continuous Dispensing Timer (S1 Dip Switch 5 & 6) - Hoshizaki FS-1022MLJ-C Service Manual

Modular cubelet serenity series with src-10j, src-14j
Table of Contents

Advertisement

2. BC (Infrared Sensor) Shutdown Delay (S1 dip switch 1, 2, 3)

Infrared sensor shutdown delay is the delay between the infrared sensor detecting ice
(infrared sensor yellow LED flashing or steady) and the start of the shutdown sequence.
For dispenser unit applications, the ice level at shutoff may need to be adjusted
depending on the dispenser agitation or dispense method. Increasing the shutdown
delay setting allows for a higher level of ice in the bin before the icemaker shuts down.
For a typical dispenser unit application, a 100-sec. shutdown delay is recommended.
When used with a standard Hoshizaki storage bin, any shutdown delay setting is
acceptable.
Increasing the shutdown delay allows a higher level of ice in the dispensing unit/
storage bin before shutdown. This could lead to icemaker movement or ice overflow.
S1 Dip Switch Setting
No. 1
OFF
OFF
OFF
OFF

3. Drain Frequency Control (S1 dip switch 4)

The appliance is factory set for optimum performance with the 1-in-1 drain cycle. This
setting allows for removal of sediment from the evaporator every hour without interrupting
the icemaking process. An optional 1-in-12 drain cycle is available.
4. Continuous Dispensing Timer (S1 dip switch 5 & 6)
DCM models only. The dispense mode switch on DCMs must be in the "CONTINUOUS"
position for this setting to apply. The factory setting allows ice to be dispensed
continuously as long as the dispense solenoid is activated.
No. 2
No. 3
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
ON
ON
ON
ON
ON
S1 Dip Switch Setting
No. 4
OFF (1-in-1)
ON (1-in-12)
S1 Dip Switch Setting
No. 5
OFF
ON
OFF
ON
WARNING
Infrared Sensor Shutdown Delay
0 Seconds
100 Seconds (1.6 minutes) (Factory Default)
1100 Seconds (18.3 minutes)
1650 Seconds (27.5 minutes)
2200 Seconds (36.7 minutes)
0 Seconds
0 Seconds
Drain Timer Interval Drain Valve Open
1 Hour
11 Hours 45 Minutes
Dispense Time
No. 6
OFF
No Limit
OFF
20 Seconds
ON
60 Seconds
ON
No Limit
38
2 Seconds
10 Minutes

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fs-1001mlj-cFs-1500mlj-c

Table of Contents