4. Continuous Dispensing Timer (S1 dip switch 5 & 6)
The dispense mode switch must be in the "CONTINUOUS" position for this setting to
apply. The factory setting allows ice to be dispensed continuously on push button models
and for a maximum of 60 sec. on Opti-Serve models.
5. Bin Control Selector (S1 dip switch 7)
The appliance is factory set for mechanical bin control operation. No adjustment is
required. In the factory default position (S1 dip switch 7 in the off position), the gear
motor delay after the upper float switch closes is 5 seconds. WARNING! Do not adjust
S1 dip switch 7 out of the factory default position. This dip switch must be left in
the factory default position or the appliance will not operate correctly.
S1 Dip Switch
Setting
No. 7
OFF
Mechanical Bin Control
Infrared Sensor with
ON
Mechanical Bin Control Backup
6. Bin Control Shutdown Delay (S1 dip switch 8)
Factory set for normal operation. No adjustment is required. The shutdown delay is the
time between the mechanical bin control proximity switch opening and the control board
shutting off the appliance.
7. Factory Use (S1 Dip Switch 9 & 10)
Factory set for optimum performance. Do not adjust.
S1 Dip Switch Setting
No. 5
No. 6
OFF
OFF
ON
OFF
OFF
ON
ON
ON
Bin Control Application
S1 Dip Switch
Bin Control #1
Setting
Shutdown Delay
No. 8
OFF
0.25 Seconds
ON
6.7 Seconds
37
Dispense Time
No Limit
20 Seconds
60 Seconds
No Limit
Gear Motor Delay
5 seconds
30 seconds