PowerWalker 1000 User Manual

Line interactive sinewave ups
Hide thumbs Also See for 1000:

Advertisement

USER MANUAL
1000VA/1500VA
Line Interactive Sinewave UPS
(220/230/240VAC)
Version: 1.4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PowerWalker 1000

  • Page 1 USER MANUAL 1000VA/1500VA Line Interactive Sinewave UPS (220/230/240VAC) Version: 1.4...
  • Page 2: Table Of Contents

    Tabel of Contents SAFETY INSTRUCTION ..............1 1. Introduction ................3 2. Package Contents ................ 3 3. Product Overview ................ 3 4. Installation ................. 4 5. Battery Replacement ..............7 6. Operation ................... 9 7. Trouble Shooting ............... 15 8. Specifications ................16...
  • Page 3: Safety Instruction

    SAFETY INSTRUCTION Thank you for purchasing this power protection product. Please comply with all warnings and operating instructions in this manual strictly. Save this manual properly and read carefully the following instructions before installing the unit. Do not operate this unit before reading through all safety information and operating instructions carefully.
  • Page 4 computer) to connect the UPS system to the building wiring outlet (shockproof outlet). Maintenance, service and faults The UPS system operates with hazardous voltages. Repairs may be carried out only by ⚫ qualified maintenance personnel. Caution - risk of electric shock. Even after the unit is disconnected from the mains ⚫...
  • Page 5: Introduction

    1. Introduction This product is an intelligent line interactive sinewave UPS (Uninterruptible Power Supply) which is designed to protect your personal computer or sensitive electronic equipment from all forms of power interference, including complete power failure. 2. Package Contents NOTE: Before installation, please inspect the unit. Be sure that nothing inside the package is damaged.
  • Page 6: Installation

    4. Installation Before installing the UPS, please read below to select a proper location to install the UPS. ⚫ UPS should be placed on the flat and clean surface. Place it in an area away from vibration, dust, humidity, high temperature, flammable liquids and gases, corrosive and conductive contaminants.
  • Page 7 Step 1: UPS Input Connection Plug the UPS into a two-pole, three-wire, grounded receptacle only. Avoid using extension cords. For the best results, suggest to charge the battery at least 5 hours before initial use. The unit charges its battery while connecting to the utility. Note: Do not expect full battery run capability during this initial charge period.
  • Page 8 Step 5: Turn On the UPS Before using the UPS, be sure to remove this label from LCD remote panel module. To turn on the UPS, simply press the ON/OFF button on the front panel for 2 seconds. UPS will beep once and LED bars will light up with different colors in order of light blue, orange, yellow, green, blue, purple and scroll from bottom to top in 6 secs.
  • Page 9: Battery Replacement

    5. Battery Replacement Please read all of the WARNINGS and CAUTIONS before attempting to service the batteries. Typical battery life is 3 to 5 years. Environmental factors do affect battery life. High temperatures, poor utility power, and frequent, short duration discharges have a negative impact on battery life.
  • Page 10 Please follow below steps to replace the batteries if necessary. Step 1: Turn off the equipment that is plugged into the output of the UPS. Step 2: Turn off the UPS. Step 3: Remove AC input plug of the UPS from the AC wall outlet. Step 4: Remove all equipment from the output sockets of the UPS.
  • Page 11: Operation

    6. Operation Button Function Button Function ON/OFF Press and hold 2 seconds to turn on or off the UPS. ⚫ Hold “on/off” button for 10 seconds can reset the unit in case of ⚫ communication failure between remote panel and UPS. Quick press 5 times to reset pairing when wireless transmission ⚫...
  • Page 12 Load information Indicates the load level by 0-24%, 25-49%, 50-74% and 75-100%, or overload alarm. Mode operation information UPS operates on the Line mode. UPS operates on the AVR mode. UPS operates on the Battery mode. Setting of LED bars. Indicates PC’s CPU temperature (C) Setting the temperature alarm level.
  • Page 13 Warning Indicator Display Warning Flashing/on Alarm Over-current on output Flashing every 0.5 secs Sounding every 0.5 secs Overload Flashing every 0.5 secs Sounding every 0.5 secs Low battery Flashing every 0.5 secs Sounding every 1 sec Battery replacement or Sounding every 2 secs battery is not connected.
  • Page 14 On-Off RGB LED OFF LED ON(default) ENERGY SAVING Brightness of Normal(default) RGB LED High Normal(default) Scrolling speed of RGB LED High Breath(default) Scrolling Effects of RGB Solid White Orange Yellow(default) Green Color selection of RGB LED in Blue Purple Line mode Others White Orange...
  • Page 15 Others White Orange Yellow Green Color selection of RGB LED in Blue(default) Purple Battery mode Others Display Setting display information will be switched in turns by pressing “UP/DOWN” button. The LCD The selectable information is switched as below order: input voltage, input frequency, battery voltage, battery capacity, estimated backup time, output voltage, output frequency, output in kW, output load percentage, NiMH battery voltage, PC CPU frequency, PC CPU temperature, CPU utilization, panel board firmware version, Base...
  • Page 16 Selectable Selectable LCD Screen LCD Screen Information Information PC CPU Battery temperature Capacity Estimated backup time utilization Panel board Output firmware Voltage version Output Firmware Frequency version of docking base board Output in UPS control board firmware version...
  • Page 17: Trouble Shooting

    7. Trouble Shooting If the UPS system does not operate correctly, please solve the problem by using the table below. Problem/Fault code Possible Cause/Fault Event Solutions UPS will not be turned on Hold the On/Off button too Press and hold the On/Off button after pressing On/Off short.
  • Page 18: Specifications

    Contact your dealer. a constant alarm. problem. 8. Specifications Model 1000 1500 CAPACITY 1000 VA / 600 W 1500 VA / 900 W Input Voltage 220/230/240 VAC Input Voltage Range 162~290 VAC Output Voltage Regulation +/-10% (Batt. Mode) Transfer Time Typical 6 ms, 10 ms max.