Master Programming Mode Chart - Pentair SOFTFLO 5600 Service Manual

Water softening system
Table of Contents

Advertisement

Available languages

Available languages

MASTER PROGRAMMING MODE CHART

Caution: Before entering Master Programming, please contact your local professional water dealer.
Abbreviation
DF
VT
CT
NT
Number of Tanks
TS
C
H
Feedwater Hardness
Reserve Selection
RS
SF
RC
Fixed Reserve Capacity
DO
RT
BW, BD, RR, BF
Regen Cycle Step Times
D1, D2, D3, D4, D5,
Day of Week Settings
D6, & D7
CD
FM
Flow Meter Type
K
Meter Pulse Setting
NOTE: Some items may not be shown depending on timer configuration. The timer will discard any changes and exit Master
Programming Mode if any button is not pressed for sixty seconds.
Master Programming Options
Parameter
Option
Abbreviation
Display Format
dF1b
dF2b
Valve Type
UFbd
UFtr
Othr
Control Type
Tank in Service
Unit Capacity
Safety Factor
Day Override
Regen Time
Current Day
P0.7
P1.0
P1.5
P2.0
GAL
Gallons
Ltr
Liters
Standard Downflow/Upflow Single Backwash
Standard Downflow/Upflow Double Backwash
Fltr
Filter
Upflow Brine First
Upflow Filter
Other
Fd
Meter (Flow) Delayed
FI
Meter (Flow) Immediate
tc
Time Clock
dAY
Day of Week
1
Single Tank System
2
Not Used
U1
Tank 1 in Service
U2
Not used
Unit Capacity (Grains)
Hardness of Inlet Water
SF
Percentage Safety Factor
rc
Fixed Reserve Capacity
Percentage of the system capacity to be used as a reserve
Fixed volume to be used as a reserve
The system's day override setting
The time of day the system will regenerate
The time duration for each regeneration step. Adjustable from OFF and
0-199 minutes.
NOTE: NOTE: If "Othr" is chosen under "Valve Type", then R1, R2, R3,
etc, will be displayed instead
Regeneration setting (On or OFF) for each day of the week on day-of-
week systems
The Current day of the week
t0.7
3/4" Turbine Meter
3/4" Paddle Wheel Meter
t1.0
1" Turbine Meter
1" Paddle Wheel Meter
t1.5
1.5" Turbine Meter
1.5" Paddle Wheel Meter
2" Paddle Wheel Meter
Gen
Generic or Other Meter
Meter pulses per gallon for generic/other flow meter
Options
PENTAIR SOFTFLO 5600 Service Manual • 11

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

40022174002162

Table of Contents