Fleck 6700XTR Downflow
Service Manual
TABLE OF CONTENTS
INSTALLATION ......................................................................2
TIMER OPERATION ..............................................................2
METER ASSEMBLY ...............................................................13
NON-METALLIC .....................................................................14
JOB SPECIFICATION SHEET
NOTE: Some options may not be available depending on valve model or
other options chosen.
Circle and/or fill in the appropriate data for future reference.
1. System Type:
A. Meter Immediate
B. Time Clock Delayed
C. Volume Override Delayed
D. Volume Override Immediate
E. Meter Delayed Weekly Reserve
F. Meter Delayed Variable Reserve
G. Meter Delayed Fixed Reserve
2. Valve Type:
A. 56XT/6700
B. Proprietary C
3. Regenerant Flow:
A. Downflow
B. Upflow
C. Downflow Double Backwash
D. Upflow Backwash
E. Filter
F. Upflow Variable Flow
4. Display Format:
A. U.S.
B. Metric (French Degrees, German Degrees, or PPM)
5. Unit Capacity: ��������� Grains/French Degrees/German Degrees/PPM
6. Water Hardness: ������� Grains/French Degrees/German Degrees/PPM
7. Capacity Safety Factor:
Zero or______________________________%
8. Volume Override: ����������������������������(Gallons or M
9. Regeneration Day Override:
A. Off
B. Every ______________________________________________ Days
10. Regeneration Time:
A. Delayed __________________________________________ AM/PM
B. Metered Immediate
11. Regeneration Cycle:
A. Step #1 _ _ : _ _ : _ _
B. Step #2 _ _ : _ _ : _ _
C. Step #3 _ _ : _ _ : _ _
D. Step #4 _ _ : _ _ : _ _
E. Step #5 _ _ : _ _ : _ _
12. Media Volume: ���������������������������������� (CuFt or Liter)
13. Salt Dosage: ��������������������������� (lbs/CuFt or grams/Liter)
14. BLFC Size: _____________________________________________ gpm
15. Auxiliary Relay:
A. Enabled
a. Auxiliary Relay Start 1 _ _ : _ _ : _ _
b. Auxiliary Relay End 1 _ _ : _ _ : _ _
c. Auxiliary Relay Start 2 _ _ : _ _ : _ _
d. Auxiliary Relay End 2 _ _ : _ _ : _ _
B. Disabled
16. Chemical Pump:
A. Enabled
B. Disabled
17. CPO Aux Relay Volume: ������������������������� (Gallons or M
18. CPO Aux Relay: _ _ : _ _ : _ _
19. Flow Meter Size:
A. 0.75" Paddle
B. 0.75" Turbine
20. Generic Flow Meter for Maximum Flow Rate:
Add_____Gallons every _ _
)
3
)
3
42132 Rev E
JL10
Need help?
Do you have a question about the Fleck 6700XTR and is the answer not in the manual?
Questions and answers
Alarm went off and I cannot stop it by unplugging. No err code