  • Page 1 DOMEKT C8 automation USER MANUAL...
  • Page 2: Table Of Contents

    3.2.4. Keypad lock ......................................21 3.3. Control via smartphone ....................................21 3.3.1. Connection to the air handling unit with a “Komfovent Control” app ................21 3.4. Control via computer ....................................... 23 3.4.1. Turning on/off and changing operation modes ......................... 25 3.4.2.
  • Page 3: Introduction

    (heating mode) or colder (cooling mode) than user set temperature air will be supplied. Selection of temperature control is described in chapter “Control and Settings”. Depends on the equipment supplied. UAB KOMFOVENT we reserve the right to make changes without prior notice DOMEKT_C8_guide_21-07...
  • Page 4: Standard Operating Modes

    Intensity Ventilation intensity 20%. of extract air 20°C 20°C 20°C 20°C temperature These settings may be changed (see “Control and Settings”). UAB KOMFOVENT we reserve the right to make changes without prior notice DOMEKT_C8_guide_21-07...
  • Page 5: Eco Mode

    As air impurity and humidity control methods slightly differ, the air quality control function is divided into: • Impurity control Impurity function is controlled via the following sensors: CO2 – carbon dioxide concentration sensor [0...2000 ppm]; VOC – air quality sensor [0...100 %]; UAB KOMFOVENT we reserve the right to make changes without prior notice DOMEKT_C8_guide_21-07...
  • Page 6 To use a DX unit or a water cooler for dehumidification of supply air, activate an option “Allow dehumidifying with cool- ing” (see “Control Sequence Settings”). An option to enter a value for desired humidity will appear in the settings of standard ventilation modes. UAB KOMFOVENT we reserve the right to make changes without prior notice DOMEKT_C8_guide_21-07...
  • Page 7: Control And Settings

    Main screen Function icons 16:30 16:30 Fan intensity Icon of an activated mode 22,0 °C NORMAL 30 % RH AUTO Time Menu AUTO function button function button button UAB KOMFOVENT we reserve the right to make changes without prior notice DOMEKT_C8_guide_21-07...
  • Page 8 ECO mode There is a cooling demand, but it is Outside air temperature being blocked by the ECO modes ECO mode on. Air flow reduction. Air filters UAB KOMFOVENT we reserve the right to make changes without prior notice DOMEKT_C8_guide_21-07...
  • Page 9: Parameter Overview

    3. A symbol will appear in the centre of the home screen indicating an operating mode which will start soon. 16:30 16:30 16:30 TURN ON? NORMAL IŠJUNGTA AUTO AUTO AUTO UAB KOMFOVENT we reserve the right to make changes without prior notice DOMEKT_C8_guide_21-07...
  • Page 10: Turning Off

    Operation modes Operation modes 16:30 KITCHEN 300 min. AWAY NORMAL MINIMALUS NORMALUS INTENSIVE BOOST INTENSYVUS MAKSIMALUS INTENSIVE KITCHEN FIREPLACE VIRTUVĖ ŽIDINYS 0 min. AUTO OVERRIDE HOLIDAYS OVERRIDE HOLIDAYS UAB KOMFOVENT we reserve the right to make changes without prior notice DOMEKT_C8_guide_21-07...
  • Page 11: Air Quantity And Temperature Settings

    Įjungta Įjungta 20 % 5,0 °C Reset settings Reset settings Reset settings Ventilation by a weekly schedule is not possible when air quality control function is activated. UAB KOMFOVENT we reserve the right to make changes without prior notice DOMEKT_C8_guide_21-07...
  • Page 12: Air Quality Control Mode Activation And Settings

    Overview Air temperature 20,0 °C Air quality Electric heater Settings 200 ppm TURN OFF Reset settings Reset settings 16:30 16:30 TURN ON? AIR QUALITY IŠJUNGTA AUTO AUTO UAB KOMFOVENT we reserve the right to make changes without prior notice DOMEKT_C8_guide_21-07...
  • Page 13: Eco Mode Activation And Settings

    BOOST Delete a row (event) WORKING WEEK Add a row Start 07:59 Add a sheet WORKING WEEK 00:00 06:00 06:00 06:00 08:00 16:00 20:00 20:00 22:30 00:00 UAB KOMFOVENT we reserve the right to make changes without prior notice DOMEKT_C8_guide_21-07...
  • Page 14 8. To add another sheet, press + at the bottom of the window (maximum 4 sheets). CUSTOM Scheduling CUSTOM Weekdays CUSTOM CUSTOM CUSTOM CUSTOM CUSTOM Start Operation mode 23:59 STANDBY 00:00 00:01 00:00 00:01 00:00 00:01 AWAY 06:00 NORMAL INTESIVE 00:00 BOOST UAB KOMFOVENT we reserve the right to make changes without prior notice DOMEKT_C8_guide_21-07...
  • Page 15: Main Settings

    Time/Date – setting the time and date that are used for a week- Time Touch sound 14:02 Click ly operation schedule or other functions. Month/Day Alarms sound 12/10 Year 2018 UAB KOMFOVENT we reserve the right to make changes without prior notice DOMEKT_C8_guide_21-07...
  • Page 16: Advanced Settings

    Outdoor humidity Impurity control Impurity control None None Humidity control Humidity control Sensor 1 Sensor 1 Sensor 1 Sensor 2 Outdoor humidity None Outdoor humidity Minimum intensivity None UAB KOMFOVENT we reserve the right to make changes without prior notice DOMEKT_C8_guide_21-07...
  • Page 17 This function is sufficient to ensure frost protection for temperatures up to -10°C. Available only if optional fire damper controller is configured and connected. Refer to Fire damper controller manual for more information. UAB KOMFOVENT we reserve the right to make changes without prior notice DOMEKT_C8_guide_21-07...
  • Page 18 • No internet access – AHU is connected to LAN network and communicates with router, but internet is not accessible. • Connected – AHU has internet access. UAB KOMFOVENT we reserve the right to make changes without prior notice DOMEKT_C8_guide_21-07...
  • Page 19: Alarms

    In the „Overview“ screen, menu „About device“ displays information about AHU type, firmware versions and serial num- ber. By pressing C8 ID line, QR code will be generated, that can be used when connecting via Komfovent Control mobile app. About device...
  • Page 20: Control Panel C6.2

    4. To save your changes, press the ON/OFF button and hold it for 5 seconds until you hear a beep. Briefly press the ON/ OFF button to return without saving. UAB KOMFOVENT we reserve the right to make changes without prior notice DOMEKT_C8_guide_21-07...
  • Page 21: Keypad Lock

    Connect AHU to the network router with Internet access and check is DHCP activated in the control panel (see Advanced Settings → Connectivity) to assign a free IP address. Launch a “Komfovent Control” app in your smartphone (phone must have Internet access). When connecting for the first time, you will have to enter the device ID number or scan a QR code located on the front of the controller board (see “Installation Manual”) or on the AHU door.
  • Page 22 AUTO Most of “Komfovent Control” app and C6.1 control panel screens are very similar, so you can follow the chapter “C6.1 Control Panel” to perform necessary changes or settings. Additionally in the “Komfovent Control” app you can change user password, synchronize system clock or review privacy policy if needed.
  • Page 23: Control Via Computer

    Should you forget a changed password, it can be reset to the initial “user”. To do this, you must restore the factory settings for the air handling unit using control panel. UAB KOMFOVENT we reserve the right to make changes without prior notice DOMEKT_C8_guide_21-07...
  • Page 24 | Month | Total | Month | Total SCHEDULING SCHEDULE OPERATION PROGRAM 4:00 8:00 12:00 16:00 20:00 24:00 WORKING WEEK STAY AT HOME OFFICE CUSTOM MODIFY > UAB KOMFOVENT we reserve the right to make changes without prior notice DOMEKT_C8_guide_21-07...
  • Page 25: Turning On/Off And Changing Operation Modes

    Button of a selected mode will change its colour: CONTROL OPERATION MODES OPERATION CONTROL OPERATION TIMER, min AUTO AWAY BOOST ACTIVATE KITCHEN FIREPLACE HOLIDAYS MODIFY > MODIFY > UAB KOMFOVENT we reserve the right to make changes without prior notice DOMEKT_C8_guide_21-07...
  • Page 26: Parameter Overview

    Air heater Heat exchanger 10 h 10 h 10 h 10 h | Month | Total | Month | Total | Month | Total | Month | Total UAB KOMFOVENT we reserve the right to make changes without prior notice DOMEKT_C8_guide_21-07...
  • Page 27: Air Quantity And Temperature Settings

    4 t. per day Electric heater Electric heater Electric heater Period Activate by contact 2018-12-24 / 2019-01-02 All time Delayed start, min Delayed stop, min SAVE CHANGES RESTORE TO DEFAULT UAB KOMFOVENT we reserve the right to make changes without prior notice DOMEKT_C8_guide_21-07...
  • Page 28: Eco And Auto Mode Settings

    16:00 20:00 24:00 WORKING WEEK STAY AT HOME OFFICE CUSTOM MODIFY > Ventilation by a weekly schedule is not possible when air quality control function is activated. UAB KOMFOVENT we reserve the right to make changes without prior notice DOMEKT_C8_guide_21-07...
  • Page 29: Creating A Weekly Schedule

    AWAY 00:00 09:00 09:00 17:00 17:00 20:00 20:00 23:00 23:00 24:00 AWAY NORMAL AWAY 00:00 09:00 09:00 22:00 22:00 24:00 ADD NEW SAVE CHANGES RESTORE TO DEFAULT UAB KOMFOVENT we reserve the right to make changes without prior notice DOMEKT_C8_guide_21-07...
  • Page 30: Alarms

    W1: Clogged air filters F3: Return water temperature low RESET CURRENT ALARMS ALARM HISTORY 19-12-2020 12:12:07 W1: Clogged air filters 18-12-2020 22:10:58 F3: Return water temperature low UAB KOMFOVENT we reserve the right to make changes without prior notice DOMEKT_C8_guide_21-07...
  • Page 31: Settings

    To discard changes, return to the start window by pressing the return button. Button RESTORE SETTINGS restores all settings to the factory defaults. Be careful not to press this button accidentally. UAB KOMFOVENT we reserve the right to make changes without prior notice DOMEKT_C8_guide_21-07...
  • Page 32 For detailed performance analysis, you may download a device logbook which contains weekly operation data. To open a logbook, you will need a “Log plotter” app that you can download from the “Komfovent” website. This data may also help in the event of a failure and may facilitate repair procedures, therefore, we recommend downloading an operation logbook and handing it over to the authorised service personnel.
  • Page 33 FILTERS – once filters are replaced, calibrate new filters and confirm replacement in the unit. CLOUD – Here it is possible to reset user password, used for log-in to Komfovent Control app, that controls AHU via smartphone. Available only if optional fire damper controller is configured and connected. Refer to Fire damper controller manual for more information.
  • Page 34: Troubleshooting

    -4 °C. device with a counter-flow heat exchanger when the outside temperature drops below -4 °C. UAB KOMFOVENT we reserve the right to make changes without prior notice DOMEKT_C8_guide_21-07...
  • Page 35 2. Supply air volume significantly ex- not worn. ceeds the extract air volume. 3. The unit door is not fully closed and different air flows are mixed. UAB KOMFOVENT we reserve the right to make changes without prior notice DOMEKT_C8_guide_21-07...
  • Page 36: Table Of Light Indicators Of The C6.2 Control Panel

    1. To unlock the control panel, press ON/ tive 2. Faulty panel. OFF button and the reset button at the same time and hold for 5 seconds. 2. Contact authorised service. UAB KOMFOVENT we reserve the right to make changes without prior notice DOMEKT_C8_guide_21-07...
  • Page 37: Periodical Maintenance

    Layout of filters and components presented in the “Installation Manual”. UAB KOMFOVENT we reserve the right to make changes without prior notice DOMEKT_C8_guide_21-07...
  • Page 38 Domekt R 200 V Domekt R 300 F Domekt CF 200 F UAB KOMFOVENT we reserve the right to make changes without prior notice DOMEKT_C8_guide_21-07...
  • Page 39 Domekt CF 200 V - 300 V Domekt CF 250 F UAB KOMFOVENT we reserve the right to make changes without prior notice DOMEKT_C8_guide_21-07...
  • Page 40: Device Maintenance Journal

    The following table is for recording performed maintenance and repair works. The log is mandatory if the air handling unit is covered by the extended manufacturer’s warranty. Procedures performed by: Date Performed procedures/notes Name, last name, signature UAB KOMFOVENT we reserve the right to make changes without prior notice DOMEKT_C8_guide_21-07...
  • Page 41: Apendix No.1. Komfovent Control Terms Of Use And Privacy Notice

    User Manual shall prevail. The processing of this data is necessary for the operation of the KOMFOVENT CONTROL app and provision of remote control services. If you use the KOMFOVENT UAB KOMFOVENT we reserve the right to make changes without prior notice DOMEKT_C8_guide_21-07...
  • Page 42 • To analyse product operation; extended storage. • To improve the product and the KOMFOVENT CONTROL operation; UAB KOMFOVENT we reserve the right to make changes without prior notice DOMEKT_C8_guide_21-07...
  • Page 43 Internet network problems or other malfunctions. For more information about KOMFOVENT products and services visit www.komfovent.com. UAB KOMFOVENT we reserve the right to make changes without prior notice DOMEKT_C8_guide_21-07...
  • Page 44 LITHUANIA PARTNERS UAB KOMFOVENT J. PICHLER Gesellschaft m. b. H. www.pichlerluft.at TECHNINĖS PRIEŽIŪROS SKYRIUS / Ventilair group www.ventilairgroup.com SERVICE AND SUPPORT ACB Airconditioning www.acbairco.be Phone: +370 5 200 8000 Email: service@komfovent.com REKUVENT s.r.o. www.rekuvent.cz www.komfovent.com WESCO AG www.wesco.ch SUDCLIMATAIR SA www.sudclimatair.ch...