Adjusting The Air Gap; Replacing The Dust Protection Ring And Enclosure; Figure 9 Adjusting The Air Gap; Figure 10 Lifting Tab In Storage Position - KEB COMBISTOP 38 Instruction Manual

Theater load brake size 10
Hide thumbs Also See for COMBISTOP 38:
Table of Contents

Advertisement

Installation
4.3.5

Adjusting the Air Gap

1. The air gap should be between 1.3 and 1.5mm. Place a feeler gauge between the
armature and magnet as shown above.
2. Tighten/loosen the nuts equally until the air gap measures between 1.3 and 1.5mm.
3. Using the feeler gauge, check the air gap around the entire circumference of the magnet
to ensure proper operation.
4.3.6

Replacing the Dust Protection Ring and Enclosure

1. When the air gap is set correctly, remove the lifting tab from the magnet assembly and
set aside, if using the optional enclosure, or replace in storage position as shown above.
26

Figure 9 Adjusting the Air Gap

Figure 10 Lifting Tab in Storage Position