Advertisement

Quick Links

Manual
Off-line Filter
FNS 040
www.argo-hytos.com
Subject to change · V 0.1 · 05.2016 · EN
Safety and operating instructions
Read safety and operating instructions before use.
Note:
The indicated data only serve to describe the product.
Specifications regarding the use of this product are only examples and suggestions.
Catalog specifications are no guaranteed features.
The information given does not release the user from his / her own assessments and inspection.
Our products are subject to a process of natural wear and aging.
© All rights are reserved by ARGO-HYTOS GMBH, even in the event of industrial property rights.
Any right of disposal such as copying and distribution rights shall remain with us.
The picture on the title page shows a configuration example.
The delivered product may thus differ from the illustration.
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FNS 040 and is the answer not in the manual?

Questions and answers

Summary of Contents for Argo-Hytos FNS 040

  • Page 1 Our products are subject to a process of natural wear and aging. © All rights are reserved by ARGO-HYTOS GMBH, even in the event of industrial property rights. Any right of disposal such as copying and distribution rights shall remain with us.
  • Page 2: Table Of Contents

    Off-line Filter FNS 040 Contents Contents ..................................2 About this documentation ............................4 Applicability of this documentation ........................... 4 Required and supplementary documentation ........................4 Presentation of information ............................... 4 1.3.1 Safety instructions ................................4 1.3.2 Symbols .................................... 5 1.3.3 Terms ....................................
  • Page 3 15.2 Technical data ................................. 23 15.3 Operating conditions ............................... 24 15.4 Hydraulic circuit diagram ..............................24 Appendix ..................................25 16.1 Spare parts list ................................. 25 Installation declaration..............................26 Page 3 www.argo-hytos.com Subject to change · V 0.1 · 05.2016 · EN...
  • Page 4: About This Documentation

    This documentation is applicable for the following product: › Off-line Filter FNS 040 This documentation is written for technicians, operators, service engineers and system operators. This document contains important information for safe and appropriate assembly, transport, activation, operation, usage, servicing, dismantling and simple troubleshooting.
  • Page 5: Symbols

    In this documentation the following terms are used: Term Meaning Table 4: Terms 1.3.4 Abbreviations In this documentation the following abbreviations are used: Term Meaning Off-line filter with flow control valve Table 5: Abbreviations Page 5 www.argo-hytos.com Subject to change · V 0.1 · 05.2016 · EN...
  • Page 6: Safety Instructions

    Therefore only use this product in safety-related applications if this use is explicitly specified and permitted in the product documentation, e.g. in explosion protection areas or in safety-related parts of a control system (functional safety). ARGO-HYTOS GMBH assumes no liability for damages resulting from improper use. The risks associated with improper use are solely with the user.
  • Page 7: General Safety Instructions

    › Observe all instructions on the product. › People who assemble, operate, disassemble or maintain ARGO-HYTOS products may not do so under the influence of alcohol, other drugs or medications that affect the responsiveness. › Only use manufacturer-approved accessories and spare parts, in order to prevent personal danger due to unsuitable spare parts.
  • Page 8: General Instructions

    Do not use aggressive cleaning agents for cleaning. Clean the product with a suitable cleaning fluid. › Do not use a high pressure cleaner. › Do not use compressed air to clean function interfaces such as seal areas. Page 8 www.argo-hytos.com Subject to change · V 0.1 · 05.2016 · EN...
  • Page 9: Scope Of Delivery

    4. Scope of delivery The package includes: › 1 Off-line Filter FNS 040 › 1 Operating manual Page 9 www.argo-hytos.com Subject to change · V 0.1 · 05.2016 · EN...
  • Page 10: About This Product

    Performance specification The off-line filter FNS 040 is a device for filtration of hydraulic fluids and lubricants in the bypass flow. A separate installation in the bypass or cooling circuit for fine filtration and discharge of the full flow filter is just as possible as the filtration of fresh oil and the cleaning (flushing) of polluted systems for wear protection of components and systems.
  • Page 11: Identification Of The Product

    3 Filter fineness 6 Address NOTE Nameplates are documents which must not be changed or removed. › Damaged or lost nameplates have to be replaced true to the original. Page 11 www.argo-hytos.com Subject to change · V 0.1 · 05.2016 · EN...
  • Page 12: Transport And Storage

    Storage in the immediate vicinity of chemically active substances such as acids, alkalis, salts, organic solvents and rechargeable batteries is prohibited. The ambient temperature during storage of the off-line filter FNS 040 should be between +5 °C and +30 °C at a humidity of max. 80 %.
  • Page 13: Assembly

    Assembly is carried out by mounting the off-line filter on site. Proceed with the following steps: Attach the off-line filter FNS 040 - as shown - vertically in close proximity to the operation site by four screws M8 and matching washers ø 8,4.
  • Page 14: Commissioning

    Manually turn the cover until it stops; a gap between cover and housing may remain visible (see Figure 3). Fig. 3: Gap at the filter cover After switching on › Check the filter unit for leaks. Page 14 www.argo-hytos.com Subject to change · V 0.1 · 05.2016 · EN...
  • Page 15: Operation

    In order to prevent a short circuit of the oil flow, the distance between the suction and pressure connection should be kept as large as possible. The operation of the off-line filter FNS 040 is depending on the machine / system, in which the off-line filter is integrated and thus cannot be further described here.
  • Page 16: Maintenance / Repair

    Risk of burns Contact temperatures according to DIN EN563 (3) and DIN EN13202 (4) may be exceeded during operation. › Allow the filter to cool down before touching it. Page 16 www.argo-hytos.com Subject to change · V 0.1 · 05.2016 · EN...
  • Page 17: Maintenance

    2. Attach the filter element in arrow direction 2 and lock it in arrow direction 1. Fig. 6: Attaching the filter element Page 17 www.argo-hytos.com Subject to change · V 0.1 · 05.2016 · EN...
  • Page 18: Installing The Filter Element

    2. Screw in the cover manually until it stops. A gap between cover and filter pipe may remain visible (see Chapter 8.1 "Before commissioning" / Fig. 3) Fig. 7: Installing the filter element Page 18 www.argo-hytos.com Subject to change · V 0.1 · 05.2016 · EN...
  • Page 19: Decommissioning

    11. Decommissioning The off-line filter is a device which does not have to be taken out of operation. Page 19 www.argo-hytos.com Subject to change · V 0.1 · 05.2016 · EN...
  • Page 20: Disassembly

    12. Disassembly The off-line filter is a device which does not have to be dismantled. Page 20 www.argo-hytos.com Subject to change · V 0.1 · 05.2016 · EN...
  • Page 21: Disposal

    13. Disposal › Careless disposal of the filter FNS 040 and the hydraulic fluid can lead to environmental pollution. › Therefore, dispose of the filter unit and the hydraulic fluid in accordance with the national regulations of your country. ›...
  • Page 22: Troubleshooting

    Viscosity too high  Warm up the medium › Leak on the suction side  Replace suction hose or seal connection points (re-tighten them) Table 7: Fault table Page 22 www.argo-hytos.com Subject to change · V 0.1 · 05.2016 · EN...
  • Page 23: Technical Data

    0 - 2,7 bar red: from 2,7 bar upwards Tare weight approx. 7 Dimensions (length x width x height) 320x560 / 572x270 (400) Table 8: Technical data Page 23 www.argo-hytos.com Subject to change · V 0.1 · 05.2016 · EN...
  • Page 24: Operating Conditions

    Hydraulic circuit diagram Fig. 9: Hydraulic circuit diagram 1 Clogging indicator 4 Pressure limiting valve 2 Filter 5 Flow control valve 3 Outlet "B" 6 Inlet "A" Page 24 www.argo-hytos.com Subject to change · V 0.1 · 05.2016 · EN...
  • Page 25: Appendix

    FNS 060.1530 VSK2-M2-100/S/M FNS 060.1540 VSK2-M2-120/S/M FNS 060.1550 VSK2-M2-160/S/M Assembly kit consisting of 2 clips Cover complete FNA 008.1250 incl. Pos. 1 Table 9: Spare parts list Page 25 www.argo-hytos.com Subject to change · V 0.1 · 05.2016 · EN...
  • Page 26: Installation Declaration

    17. Installation declaration Einbauerklärung Installation declaration ARGO-HYTOS Polska sp. z o.o. Władysława Grabskiego 27 32-640 Zator Tel.: +48 33 873 16 52 Fax: +48 33 873 19 15 www.argo-hytos.com Die Einbauerklärung gilt für folgendes Gerät: The installation declaration applies to the following unit:...
  • Page 27 ARGO-HYTOS worldwide Benelux ARGO-HYTOS B. V. info.benelux@argo-hytos.com Brazil ARGO-HYTOS AT Fluid Systems Ltda. info.br@argo-hytos.com China ARGO-HYTOS Fluid Power Systems (Yangzhou) Co., Ltd. info.cn@argo-hytos.com ARGO-HYTOS Fluid Power Systems (Beijing) Co., Ltd. info.cn@argo-hytos.com ARGO-HYTOS Hong Kong Ltd. info.hk@argo-hytos.com Czech Republic ARGO-HYTOS s.r.o info.cz@ argo-hytos.com...