Available languages

Table of burner and nozzle specifications
GB
Table 1
Burner
Rapid (Large)
(R)
Semi-rapid
(Medium) (S)
Auxiliary
(Small) (A)
Supply
pressure
*
At 15°C and 1013 mbar - dry gas
**
Propane P.C.S. = 50.37 MJ/kg
***
Butane P.C.S. = 49.47 MJ/kg
Natural P.C.S. = 37.78 MJ/m³
ø 180
S
A
R
KN6M6SA/FR
KN6M66SA/FR
WARNING! The glass
lid can break in if it is
heated up. Turn off all
the burners and the
electric plates before
closing the lid.
18
Diameter
Thermal power
(mm)
kW (p.c.s.*)
Nominal
Reduced
100
3.00
0.70
75
1.90
0.40
55
1.00
0.40
Nominal (mbar)
Minimal (mbar)
Maximised (mbar)
Liquid gas
Bypass
Nozzle
Capacity*
1/100
1/100
g/h
(mm)
(mm)
***
41
86
218
30
70
138
30
50
73
28-30
20
35
TEC H NICA L DA TA
Oven d im en sions
(Lx DxH )
Volum e
U se ful
m easurem ents
relating to th e oven
com partment
Pow er s up ply
voltag e an d
freq uency
B urners
EN ERG Y LA BEL
Natural gas
Nozzle
Capacity*
1/100
l/h
(mm)
**
214
116
286
136
106
181
71
79
95
37
20
25
17
45
25
32x43,5x43 cm
56 l
width 42 cm
de pth 46 cm
heigh t 8,5 cm
see d ata plate
may be adapted for use with an y type of
gas sh ow n on the data plate
Dire ctive 2002/40 /E C on the lab el of
electric ove ns. Stand ard EN 50304
En erg y consu mption for N atural
convection – heating m od e:
En erg y consu mption for F orce d
F an
convection – heating m od e:
Oven;
EC D irectives: 0 6/95/EC da ted 12/1 2/06
(Low Voltage ) and su bse quent
amen dme nts –
04/10 8/EC d ated 15/12/0 4
(Electroma gnetic Co mpa tibility) and
sub seq uent ame ndm ents –
93/68/EE C dated 22/07 /93 and
sub seq uent ame ndm ents –
2002/96/EC.
1275/200 8 Stand-b y/ O ff m ode