Table 1-2 Specifications of L3A, L3C and L3E (4 / 4)
Engine model
Working voltage
Insulation resistance
Stroke
Ambient temperature for use
Working voltage
Insulation resistance
Stroke
Ambient temperature for use
Working voltage
Insulation resistance
Stroke
Ambient temperature for use
Working voltage
Insulation resistance
Stroke
Ambient temperature for use
L3A
L3C
12V - ETR: 8V or less
100 MΩ or more at DC 500V megger
(normal temperature, normal relative humidity)
13.5 ± 0.5 mm [0.53 ± 0.02 in.]
-40 to 120°C [-40 to 248°F]
12V - ETS: 10V to 15V
100 MΩ or more at DC 500V megger
(normal temperature, normal relative humidity)
10 ± 0.5 mm [0.39 ± 0.02 in.]
-30 to 120°C [-22 to 248°F]
24V - ETR: 16V or less
100 MΩ or more at DC 500V megger
(normal temperature, normal relative humidity)
13.5 ± 0.5 mm [0.53 ± 0.02 in.]
-40 to 120°C [-40 to 248°F]
24V - ETS: 20V - 30V
100 MΩ or more at DC 500V megger
(normal temperature, normal relative humidity)
10 ± 0.5 mm [0.39 ± 0.02 in.]
-30 to 120°C [-22 to 248°F]