Front Panel

Label
ON
OVL
USB
L1
L2
RS485
Test
Aux
Current Mon
Volt Mon
LEMO HV Output
Screw HV Output
The sensitivity of the current and voltage monitors are determined by the peak-to-peak output
voltage range. For example, the peak-to-peak output voltage range of the PDUS210-400 is 400 V,
so the current gain is 1.056 V/A, and the voltage gain is 0.01265 V/V.
PDUS210 V4
Function
Power indicator
Indicates an overload or shutdown state, see overload protection
USB 2.0 Type-B device connector
Uncommitted LED indicator
USB Activity indicator
Isolated RS485 interface, suits Amphenol TJ0431530000G connector
GND is the isolated ground.
+/-4V Input produces full-range output voltage. Test use only.
Connected to ADC converter, not presently used
Output current monitor, AC coupled. The gain is 0.00264 × ��
Output voltage monitor, AC coupled. The gain is 5.06/��
Suits LEMO 0B.302 Connector (e.g. FGG.0B.302.CLAD42)
Suits Amphenol TJ0331530000G connector