NEA SMART 2.0 Remote sensor
Sensor type
Precision
Protection rating
CE conformity as per
Sensor element dimensions (W x H x D in mm)
Cable length
Housing material
Housing colour
Weight
Ambient temperature
Ambient humidity
Storage/transport temperature
Usage environment
NEA SMART 2.0 Flow/Return sensor
Sensor type
Precision
Protection rating
CE conformity as per
Sensor element dimensions (W x H x D in mm)
Cable length
Housing material
Housing colour
Weight
Ambient temperature
Ambient humidity
Storage/transport temperature
Usage environment
NEA SMART 2.0 Antenna
Power supply
Radio range
Protection class/protection rating
CE conformity as per
Dimensions (W x H x D in mm)
Housing material
Housing colour
Weight
Ambient temperature
Ambient humidity
Storage/transport temperature
Usage environment
NTC 10 K
± 5% @25 °C
IP67
EN 60730
28 x 6 x 6
3 m
Sensor sheathing: PBT; cable sheathing: PVC (UL2517)
White (similar to RAL 9003)
0.065 kg
-20 °C to +60 °C
< 95% r. m., non-condensing
-25 °C to +60 °C
Indoors only
NTC 10 K
± 5% @25 °C
IP67
EN 60730
45 x 5 x 5
3 m
Sensor sheathing: Metal; cable sheathing: PVC (UL2517)
White (similar to RAL 9003)
0.065 kg
-20 °C to +60 °C
< 95% r. m., non-condensing
-25 °C to +60 °C
Indoors only
From NEA SMART 2.0 Base
25 m in buildings
III/IP30
EN 60730
186 x 22 x 11
PVC
White (similar to RAL 9010)
0.060 kg
0 °C to +50 °C
< 95% r. m., non-condensing
-25 °C to +60 °C
Indoors only
End user manual