Routine Maintenance; Replacing The Probe; Replacing The Battery; Accessories - Mastech MS8269 User Manual

Hide thumbs Also See for MS8269:
Table of Contents

Advertisement

5.1 Routine maintenance

WARNING
In order to avoid electric shock or damaging the meter, please
do not wet the interior of the meter, Always disconnect the
test tips from the input signal before remove the shell or the
battery cover.
Use a damp mop and a small amount of detergent to clean
the shell of the meter periodically. Please do not use abrasive or
chemical solvents.
If the input sockets are fouled or wet, the measurement might
be affected.
Therefore, the input sockets need to be cleaned:
Turn off the meter, and pull out all test tips from the input sockets
Clean all dirt off the sockets.
Wet a new cotton stick with cleaner or lubricant(e.g.WD-40).
Clean every socket with the cotton stick, and the lubricant can
prevent the sockets from contamination caused by high
humidity.

5.2 Replacing the Probe

If insulation on probe is damaged, replace it.
WARNING
Use meet EN 61010-031 standard, rated CAT II 600V, 10A or better
probe.

5.2 Replacing the Battery

WARNING
In order to avoid electric shock or physical hurting due to
wrong readings, please replace the battery immediately
when "
" symbol appears on the display of the meter. In
order to avoid electric shock or physical hurting, please turn
off the meter and make sure that the test tips are disconn-
ected from the circuit to be tested before taking off the
battery cover for replacing the battery.
19
Fig. 2 Replacing the Battery
Please follow the steps below to replace the battery
(also see Fig.2):
1. Turn off the power of the meter.
2. Pull out both test tips from the input sockets.
3. Use a screw driver to loosen the two screws fixing the battery
cover.
4. Take off the battery cover.
5. Take off the used battery.
6. Put a new 9V (6F22) battery in place.
7. Put the battery cover in place ,and tighten the screws.

6. Accessories

Instruction manual
Test tips
Type K thermoelectric couple TP 01
Dedicated multi-functional test sockets
Battery cover
9V Battery
1 piece
1 pair
1 pair
1 piece
00-05-1658

Advertisement

Table of Contents
loading

Table of Contents