4.2.6 Humming ON/OFF
Funct
Description
If measured resistance
is less than 70Ω,
buzzer will sound
Overload protection: 250V DC or AC (rms)

4.2.7 Capacitance

Range
Resolution
20nF
1nF
200nF
0.1nF
±(4% of reading +8 graduation)
2µF
1µF
200µF
0.1µF
±(4% of reading +15 graduation)
Overload protection: self-recovery fuse(F500mA/250V)

4.2.8 Inductance

Range
Resolution
20mH
10uH
200mH
0.1mH
2H
1mH
20H
10mH
Overload protection: self-recovery fuse(F500mA/250V)

4.2.9 Temperature

Range
Resolution
o
o
-20 C~0 C
±(5.0% of reading +4 graduation)
o
o
o
1 C~400 C
1 C
±(1.0% of reading +3 graduation)
o
o
401 C~1000 C
Error of thermoelectric couple is not included in temperature parameters.
Overload protection: self-recovery fuse (F500mA/250V)
Test condition
Open circuit
voltage:
500mV
Accuracy
Accuracy
±(3% of reading +8
graduation)
Accuracy
±2.0% of reading
17

4.2.10 DC Current

Range
Resolution
200mA
0.1mA
±(1.5% of reading +1 graduation)
10A
10mA
±(2.0% of reading +5 graduation)
Overload protection: self-recovery fuse (F500mA/250V); No fuse
protection for the range of 10A.
Max. input current: mA: DC 200mA or AC (effective value);
10A: DC 10A or AC (effective value)
When measuring current which is greater than 5A, do not conduct
measurements consecutively for more than 4 minutes. After the
measurements are completed, do not conduct new current
measurements until 10 minutes later.

4.2.11 AC Current

Range
Resolution
200mA
0.1mA
±(1.8% of reading +3 graduation)
10A
10mA
±(3.0% of reading +7 graduation)
Overload protection: self-recovery fuse (F500mA/250V); No fuse
protection for the range of 10A.
Max. input current: mA: DC 200mA or AC (effective value);
10A: DC 10A or AC (effective value)
When measuring current which is greater than 5A, do not conduct
measurements consecutively for more than 4 minutes. After the
measurements are completed, do not conduct new current
measurements until 10 minutes later.
Frequency response: 40Hz-400Hz, sine wave effective value
(mean value response)

5. Meter Maintenance

Basic maintenance information is given in this section, including
instructions for replacing a fuse and replacing a batter.
Do not try to repair the meter unless you are an experienced
service staff and you can get access to information regarding
related calibration, performance tests, and services.
Accuracy
Accuracy