KARA
i
MODULAR WST
RIGGING PROCEDURES
VERSION 1.1
9.1.3
Pullback configuration setup safety limits
An M-BUMPi bar can be fixed to the bottom enclosure of a KARAi array to obtain a pullback configuration (array site
angle settable down to -90°) within the mechanical safety limits given in Table 6.
Always refer to Table 6 before setting an array in pullback configuration.
WARNING
Number of KARAi enclosures in the array
Number of SB18i enclosures in the array
Maximum array negative site angle
-90°
Figure 35: Pullback configuration example with site angle -90°
KARA
i
_RM_EN_1-1
®
SYSTEM
Table 6: Mechanical safety limits in pullback configuration
w w w . l - a c o u s t i c s . c o m
12
12
9
0
4
3
-90°
-10°
-60°
6
3
2
1
-90°
-90°