CARBON TANK SOAK

Note: Your system will not be ready for use for a minimum of 48 hours while the Carbon Soak process takes place.
Please plan your installation accordingly.
Notice
Water will flow out of the outlet side of the Bypass Valve during this process. Be sure you perform this series of steps in a
location suitable for water flow.
Top View
Garden
Hose
Carbon Tank Soak
Note: Steps 1-8 should be done prior to installation
1. Connect the 1-½" threaded PVC adapter to the inlet side of the tank head.
2. Connect the 1" threaded PVC adapter into the 1-½" adapter.
3. Connect the ¾" PVC hose bib into the 1" adapter.
4. Connect your garden hose to the Hose bib adapter.
5. Repeat steps 1-4 on the Outlet side of the tank head.
6. Fill the Pentair High Flow Carbon Water Filter Tank full until water flows out of the second hose.
7. Turn the water off.
8. Allow the carbon tank to soak for at least 48 hours prior to tank installation.
INLET
OUTLET
Garden
Hose
Water Filter
1½˝ to 1˝ Threaded
PVC Adapter
To filter
head
Water
HIGH FLOW CARBON WATER FILTER SYSTEM WITH PRE-FILTER • 5
1˝ to ¾˝ Threaded
PVC Adaptor
¾˝ PVC
Garden
Hose Bib
Hose