4-2-19.

STOP_DEC

・ Feature: Stop Decoding
Length
04
Field
Length
Operation
Code
Message
Source
Status
Checksum
Stop decoding action operation.
Just like START_DEC, this is valid only when TRIGGER_MODE is set to HOST.
Operation
Message
Code
source
E5
04
Operation Code
Message
Source
Length
E5
4:Host
Bit0: retransmit
Bit1: Unused
Status
Checksum
1
The length of a packet excluding checksum
1
Packet ID
1
From The Host System to This Scan Engine
1
2
Two's complement sum of message contents
(from Length to Data Field).
41