Programming; Programming Sequence - Lang Purple Product Manual

Computer operation service troubleshooting
Table of Contents

Advertisement

PROGRAMMING SEQUENCE

The following procedure describes a standard programming sequence. Each programming prompt is shown
in the coloum DISPLAY and the required program entry is shown in the coloum ACTION.
The Control allows for a 3 second delay between each button push, if a delay of longer than 3 seconds has
occurred, the programming sequence must be re-entered.
DISPLAY
EnTer
Prod
000 F
CC0-7
FAn 01
0:00:00
000 F
ACTION
Press: Read/Clear, 1, 6, 2, 7, 3, 8
Select a Product Button 1 through 0
Enter a Cooking Temperature, 100 through 450 degrees.
Enter a Cooking Curve, 0 through 7. For a definition of Cooking curve, refer to
the DEFINITIONS section.
Select a Fan Function. 0 = Off, 1 = On. For a definition of Fan Function, refer
to the DEFINITIONS section.
Enter a Cooking Time, Hours/Minutes/Seconds up to 9:59:59.
This prompt is the beginning of the Tier 2 portion of the programming. For a
definition of Tiers refer to the DEFINITIONS section.
If, during the cooking cycle, the program calls for a change in the Cooking
Temperature or Fan Function that change can be entered at this time.
The Tier being programmed is indicated by the lighted Tier Lamp below the
Display.
If Tier 2, Tier 3, or Tier 4 programming is required, repeat the above entries as
prompted by the display (Cooking Curve is entered in Tier 1 only ) until all
necessary Tiers are programmed, then proceed to the steps shown below.
If the program requires one Tier programming only DO NOT repeat the above
procedures, proceed to the steps shown below.

PROGRAMMING

IMPORTANT
4