DEFINITIONS

CONTROL PANEL BUTTONS

1 -O
A - E
MAN PROG
READ/CLEAR
TEMP

PROGRAMMING TERMS

COOKING CURVE
Product Buttons. These are the buttons where the product programs are
stored. Pressing a Product Button will heat the oven to the programmed
temperature.
Shelf Buttons. The control is capable of timing each shelf individually.
Pressing a Product Button then a Shelf Button will start the countdown timer.
The MANUAL PROGRAM button allows the operator to enter a temporary
product program without being required to input the programming code. The
temporary program is erased when the oven is turned off or when a new
program is entered. Time and temperature are the only parameters that can be
entered in the Manual Program mode.
The READ/CLEAR button has several functions.
It is always the first button pressed when entering programming
codes.
Pressing it twice then pressing a Product Button will "read-back"
the program in that product button.
Pressing and holding the button down until "88888" appears in
the display will cancel the current mode of the control and return
the display to "Enter".
When the Temperature Recall Button is pressed, the display will indicate the
internal oven temperature. When released the display will revert to the
previous readout.
Cooking curve is a function of the computer that controls the cooking time.
If the temperature of the oven is lower than the programmed temperature,
the control will slow the timer down to compensate for the lower cooking
temperature. Cooking Curves from 0 - no time adjustment to 7 - maximum
adjustment are available. Cooking Curve 3 is the most commonly used.
However, as a general rule the longer the cooking time the lower the
cooking curve, the shorter the cooking time the higher the cooking curve.