Table 8-1
When the VPT300 is in a tracking test, ensure a quiet environment.
Table 8-1 Testing VPT300 tracking
Test Method
● The distance between
● Speak normally and
● Use a stopwatch to
Issue 04 (2020-02-11)
8
describes how to test VPT300 tracking and troubleshoot problems.
the speaker and the
VPT300 is greater than
2 m.
continuously.
calculate the image
switching time.
Copyright © Huawei Technologies Co., Ltd.

Testing VPT300 Tracking

Test Result
The VPT300 is expected
to switch to close-up
video images of the
speaker after the
speaker talks for the
following duration:
● Sensitivity set to
High: 3-5s
● Sensitivity set to
Medium: 5-8s
● Sensitivity set to
Low: 10-20s
8 Testing VPT300 Tracking
Troubleshooting
If the VPT300 does not
switch to close-up video
images or does not switch
within 150% of the
preceding maximum
duration, perform the
following steps:
1. Follow the instructions
in
A Calibrating the
Camera
to calibrate
the camera.
2. Test VPT300 tracking
again.
3. If the fault persists,
contact Huawei
technical support
engineers.