Omron Sysmac NYP-0 Series Hardware User Manual page 76

Industrial panel pc
Table of Contents

Advertisement

3 Hardware
NYML Recommendations for Custom Cables
The following table lists the recommended cables and connectors for custom NY Monitor Link cables.
Maximum length
Manufacturer
Cable type
Category type
Cable sheath
Conductor pairs/size/type
Overall shielding
Pair shielding
Maximum outer diameter
Maximum bending radius of cable in a fixed
position
Maximum temperature for a cable in a fixed
position
RJ45 connectors
Additional Information
When making cables, connect the shield to the connectors at both ends.
 NY Monitor Link Cable Clearance
Ensure to prevent excessive strain on the connector and cable assembly.
The minimum clearance consists of the sum of:
• Connector length
• Maximum bending radius of cable in a fixed position
3-30
Item
light industrial en-
25 m
Lapp
2170196
Cat 6A
Halogen free
4 x 2 x AWG23/1
Aluminum foil
Aluminum foil
7.6 mm
31 mm
60°C
Manufacturer
Stewart Connector
Partnumber
SS39200-027 or
SS39200-030
Connector length
30 mm
Intra cabinet or
Inter cabinet
vironment
100 m
Lapp
2170614
Cat 7
Halogen free
4 x 2 x AWG23/1
Copper braid
Aluminum foil
7.7 mm
31 mm
60°C
Stewart Connector
SS39200-027 or
SS39200-030
30 mm
NY-series Industrial Panel PC Hardware User's Manual (W555)
Inter cabinet and
harsh industrial
environment
100 m
Lapp
2170466
Cat 6A
Halogen free
4 x 2 x AWG22/1
Copper braid
Aluminum foil
9.0 mm
90 mm
80°C
Lapp
21700600 (T568A)
or 21700601
(T568B)
50 mm

Advertisement

Table of Contents
loading