6-2

Power ON

This section provides Power ON details.
Precautions for Correct Use
Do not turn ON the power supply to the product when a part of a human body or a conductive
object is touching the surface of the touchscreen. Doing so will cause the touchscreen function-
ality to be disabled. Remove the conductive object and cycle the power supply to restore the
touchscreen functionality.
6-2-1

Power ON Using the Power Button

Start condition: Power is supplied to the Panel PC and the Panel PC is OFF.
1
Press the power button and release within 1 second.
Refer to 3-3 Power Button on page 3-12 for the power button location.
The Panel PC starts and the PWR LED will turn ON.
2
Wait until the PWR LED is ON and verify that the ERR LED is OFF.
The Panel PC is ON and the Operating System, if installed, starts.
6-2-2

Power ON Using the Power ON/OFF Input

Start condition: Power is supplied to the Panel PC and the Panel PC is OFF.
1
Supply an input signal to pins 3 and 4 of the I/O connector.
The input signal must remain ON for a minimum of 60 ms and a maximum of 750 ms to be
correctly detected by the Panel PC.
The Panel PC starts and the PWR LED will turn ON.
2
Wait until the PWR LED is ON and verify that the ERR LED is OFF.
The Panel PC is ON and the Operating System, if installed, starts.
Additional Information
• Refer to 4-2-2 I/O Connector Specifications on page 4-21 for connector specifications.
• Refer to 5-4-4 Wire the I/O Connector on page 5-38 for wiring details.