Section 3: Venting

Montigo supplies a variety of direct venting and termination options.
The direct vent termination location MUST be selected such that it is the
highest point in the venting assembly. It should also be selected such
that it provides the shortest vent run possible. Should it be impossible
to ensure that the termination is the highest point or to meet the
venting guidelines laid out below please contact your Montigo dealer
to discuss power venting options.
Notes For Planning Venting:
Venting can originate from the unit through the top or through the rear
Venting can terminate through the roof or through an exterior wall.
Refer to Appendix A - Termination Locations to ensure the planned
termination location is acceptable.
Once the termination location has been established, refer to the
appropriate section below for installation details
Silicone application is NOT required when joining Montigo vent
pipes and components.
Use the following instructions to convert a unit for side vent use:
vent outlet. Fasten the cover with included hardware.
Install the collars to the rear vent outlet using the included hardware.
Figure 5.
XG0228 - 021419
NOTICE
accommodate an installation. Use an alternative length to complete
your vent run.
½"
Figure 5.b
should be closed following these steps:
STEP 1: Pull the air baffle forward as far as possible and screw
the air baffle closed.