CCFS 7000 Cleaning Process Rev 1-2-0-10-20160509 Further, The Coca-Cola Company reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation to notify any person of such revision or changes.
Chapter 1: Introduction Chapter Introduction Scope This document is intended for use by any person required to clean the Coca-Cola Freestyle ® 7000 dispenser. Technical information can be found in the Coca-Cola Freestyle ® 7000 Technical Manual. Purpose This document contains cleaning processes for the Coca-Cola Freestyle ®...
Chapter 2: Cartridge Change Cleaning Chapter Cartridge Change Cleaning PERFORM THESE STEPS BEFORE INSERTING A NEW PRODUCT CARTRIDGE Step Action Remove Product Cartridge(s) from the Product Tower. Carefully clean the IPN connector(s) with a clean cloth dipped in Sanitizer until the cloth comes away clean.
Chapter 3: Daily Cleaning Chapter Daily Cleaning DAILY CLEANING OF THE COCA-COLA FREESTYLE® 7000 DISPENSER Equipment Required Ensure you have the following equipment before beginning Daily Cleaning Equipment Required 5 Gallon Bucket with Gradations (Coca- Detergent Cleanser appropriate for Cola Part #: 143317 recommended)
Page 9
Chapter 3: Daily Cleaning Diffuser Socket Brush (Coca-Cola Part #: Valve Nozzle Brush (Coca-Cola Part #: 138807) 16586) Drain Brush (Coca-Cola Part #: 28076) Clean, lint-free, soft cleaning Cloth Classified – Confidential Page 4 of 46...
Chapter 3: Daily Cleaning Cleaning Procedure Prepare Sanitizer Step Action In a clean 5 gallon Bucket, prepare 5 gallons of Kay-5 Sanitizer (two 1oz packet of Kay- 5). Use hot water. Note: Do not exceed 100 ppm Sanitizer strength as this causes damage to the equipment.
Chapter 3: Daily Cleaning Remove Parts to Clean Separately Step Action Grasp the Nozzle Tip, rotate it counter clockwise, and pull it downwards from the Nozzle. Remove the Cup Rest and Drip Tray from the dispenser and separate them by pulling up on the ring in the drip tray.
Chapter 3: Daily Cleaning Step Action Clean the Nozzle Tip, Drip Tray, and Cup Rest with warm water and Detergent Cleanser using the Parts Brush. Thoroughly rinse with warm water. Sanitize the Removed Parts Step Action Submerge the parts in Sanitizer for 2 minutes. Note: Shake the Nozzle Tip when submerging into the Sanitizer to ensure no air pockets remain.
Chapter 3: Daily Cleaning Clean the Nozzle Step Action Clean the outer Nozzle with the Diffuser Socket Brush dipped in Sanitizer until it is visibly clean. Clean the inner Nozzle with the Valve Nozzle Brush dipped in Sanitizer until visibly clean. Repeat Steps 1 and 2.
Chapter 3: Daily Cleaning Clean the User Interface Step Action Clean the Back Splash with a clean Cloth dipped in Sanitizer until the Cloth comes away clean. Clean the Dispensing Lever with a clean Cloth dipped in Sanitizer until the Cloth comes away clean.
Chapter 3: Daily Cleaning VII. Clean the Drain Area Step Action Clean the Drain Tube with the Drain Brush dipped in Sanitizer. Clean the Drip Tray Plate with a clean cloth dipped in Sanitizer. Reinstall the Drip Tray. Pour the remaining Sanitizer down the drain to clean the drain and drain line. Verify the drain functions properly.
Chapter 3: Daily Cleaning VIII. Repeat Step Action Mix a fresh batch of Sanitizer. Remove the Drip Tray. Perform Steps IIIError! Reference source not found. through VII again. Reinstall all Parts Step Action Reinstall the Nozzle Tip using a sanitary cloth. Reinstall the Cup Rest.
Chapter 3: Daily Cleaning Sanitize Brushes Step Action Soak any cleaning brushes used in a separate container of Sanitizer for 2 minutes. Agitate the Brushes to dislodge any debris and allow them to soak for an additional 2 minutes. Place the Brushes on a sanitary surface to dry before returning them to storage. Classified –...
Chapter 4: Weekly Cleaning Chapter Weekly Cleaning WEEKLY CLEANING OF THE COCA-COLA FREESTYLE® 7000 DISPENSER Equipment Required Ensure you have the following equipment before beginning Weekly Cleaning. Equipment Required 5 Gallon Bucket with Gradations (Coca- Parts Brush (Coca-Cola Part #:...
Chapter 4: Weekly Cleaning Cleaning Procedure Prepare Sanitizer Step Action In a clean 5 gallon Bucket, prepare 5 gallons of Kay-5 Sanitizer (two 1oz packet of Kay- 5). Use hot water. Note: Do not exceed 100 ppm Sanitizer strength as this causes damage to the equipment.
Chapter 4: Weekly Cleaning Clean the Ice Chute Step Action Turn off power to the dispenser and unplug it. Dip the Ice Chute Brush in Sanitizer and use it to thoroughly swab inside the Ice Chute. Clean the Ice Chute Body area with a clean cloth dipped in Sanitizer. Wait 2 minutes and then perform Steps 2 and 3 again.
Chapter 4: Weekly Cleaning III. Sanitize Brushes Step Action Soak any cleaning brushes used in a separate container of Sanitizer for 2 minutes. Agitate the Brushes to dislodge any debris and allow them to soak for an additional 2 minutes. Place the Brushes on a sanitary surface to dry before returning them to storage.
Chapter 5: Monthly Cleaning Chapter Monthly Cleaning MONTHLY CLEANING OF THE COCA-COLA FREESTYLE® 7000 DISPENSER Equipment Required Ensure you have the following equipment before beginning Weekly Cleaning. Equipment Required 5 Gallon Bucket with Gradations (Coca- Parts Brush (Coca-Cola Part #:...
Chapter 5: Monthly Cleaning Cleaning Procedure Prepare Sanitizer Step Action In a clean 5 gallon Bucket, prepare 5 gallons of Kay-5 Sanitizer (two 1oz packet of Kay- 5). Use hot water. Note: Do not exceed 100 ppm Sanitizer strength as this causes damage to the equipment.
Chapter 5: Monthly Cleaning Remove All Ice Step Action Remove all ice from the Ice Bin by activating the Ice Lever. Turn off power to the dispenser and unplug it. Remove the Ice Bin Cover. Remove all remaining ice by pouring warm (not hot) water over the ice in the Ice Bin. Classified –...
Chapter 5: Monthly Cleaning III. Remove Parts Clean Separately Step Action Inside the Ice Bin locate and remove the Cotter Pin from the Retaining Pin on the Agitator Bar. Remove the Retaining Pin from the Agitator Bar. Remove the Agitator Bar. Classified –...
Chapter 5: Monthly Cleaning Step Action Remove the Paddle Wheel. Remove the Ice Bin Divider. Clean the Removed Parts Step Action Wash your hands throroughly with warm water in a sink using detergent cleanser. Wash the Cotter Pin Retaining Pin ...
Chapter 5: Monthly Cleaning Step Action Thoroughly rinse with warm water. Clean all the parts above in the sink using warm water and Detergent Cleanser using the Parts Brush. Thoroughly rinse with warm water. Sanitize the Removed Parts Step Action Submerge the smaller parts in Sanitizer 2 minutes.
Chapter 5: Monthly Cleaning Step Action Wait 2 minutes to allow the sanitizer to work and the surfaces to air dry. VII. Repeat Step Action Mix a fresh batch of Sanitizer as described in Section I. Perform all the steps in Sections V and VI. VIII.
Chapter 6: Annual Cleaning Chapter Annual Cleaning YEARLY CLEANING OF THE COCA-COLA FREESTYLE® 7000 DISPENSER Equipment Required Ensure you have the following equipment before beginning Annual Cleaning. Equipment Required 5 Gallon Bucket with Gradations (Coca- Parts Brush (Coca-Cola Part #:...
Page 30
Chapter 6: Annual Cleaning Empty Bag in Box to be filled with Green BiB Connector (Coca-Cola Part #: 120869) Sanitizer 3/8” Tubing, ≅ 36” in length (1) (Coca- Flush Adapter (Coca-Cola Part # 28688) Cola Part # 125041 recommended) 14.5 Oetiker Clamp (1) (Coca-Cola Part...
Chapter 6: Annual Cleaning Cleaning Procedure Prepare Sanitizer Step Action In a clean 5 gallon Bucket, prepare 5 gallons of Kay-5 Sanitizer (two 1oz packet of Kay- 5). Use hot water. Note: Do not exceed 100 ppm Sanitizer strength as this causes damage to the equipment.
Chapter 6: Annual Cleaning Step Action Secure the Tubing to the Connector with an Oetiker Clamp. Remove the cap from the empty BIB and attach the Green BIB Connector to the empty BIB. Pour Sanitizer into the open end of the Tubing until the BIB is full (5 gallons). You may use the funnel from the Cleaner Cartridge Refill Kit to facilitate filling.
Page 33
Chapter 6: Annual Cleaning Step Action Insert the IPN fitting of the Pouch Filler into an empty Cleaner Cartridge Pouch. Carefully pour 680 ml of Sanitizer into the funnel of the Pouch Filler. Once the funnel and tubing are empty, gently squeeze the Cleaner Pouch to ensure as much air as possible is removed from the pouch.
Chapter 6: Annual Cleaning Clean Product Line Equipment Step Action Disconnect the green BiB Connector from the HFCS Line. Clean the green BiB Connector with the Parts Brush and Sanitizer. Rinse the connector thoroughly with Sanitizer and allow it to soak in Sanitizer for 2 minutes.
Chapter 6: Annual Cleaning Step Action Clean all IPN connectors in the cartridge shelves with a clean Cloth dipped in Sanitizer until the Cloth comes away clean. Clean all interior tower surfaces with a clean Cloth dipped in Sanitizer. Wait 5 minutes. Perform Steps 6 through 8 again.
Page 36
Chapter 6: Annual Cleaning Step Action Place both Cleaner Cartridges in Trays. Ensure the 1 flange on the neck of the cartridge is outside the tray lip, and the 2 flange is inside the tray lip. Place all 17 Cleaner Pouches (no box) in Trays. Ensure the 1 flange on the neck of the cartridge is outside the tray lip, and the 2 flange is inside the tray lip.
Page 37
Chapter 6: Annual Cleaning Step Action Do not touch the CONFIRM button. Insert a Cleaner Cartridge in Tray into the top slot of the Agitation Tower. Fill all remaining slots with Cleaner Pouches in Trays. Classified – Confidential Page 32 of 46...
Chapter 6: Annual Cleaning Clean the Product and HFCS Lines Step Action Log in as Technician. Select the UTILITIES icon to display the UTILITIES MENU. Classified – Confidential Page 33 of 46...
Page 39
Chapter 6: Annual Cleaning Step Action Select SANITIZE DISPENSER to display the SANITIZE DISPENSER screen. Select the START SANITIZATION button. Note: If the START SANITIZATION button is not enabled, check for errors or warnings regarding the Cleaner Cartridges, verify the door is open, and remove the Cleaner Cartridges and reinsert them.
Chapter 6: Annual Cleaning Step Action The dispenser now runs the cleaning process. This takes approximately 25 minutes. You can track the process with the SANITIZING PROGRESS BARS. VII. Purge Product Lines Step Action When the Sanitization Process completes the PURGE SANITIZER SOLUTION window displays.
Chapter 6: Annual Cleaning Step Action Once the process is complete the dispenser prompts you to finish. The SANITIZATION PROCEDURE COMPLETE window displays. Select the OK button. Remove all Cleaner Cartridges from the dispenser. Remove all Cleaner Cartridges from the Trays. VIII.
Chapter 6: Annual Cleaning Step Action Insert Product Cartridges into Trays and place them into their appropriate slots in the dispenser. Prime them as prompted on the screen until all products are primed and ready. Purge and Prime HFCS Step Action Disconnect the BiB of Sanitizer and attach a Flush Adapter to the green BiB Connector.
Chapter 6: Annual Cleaning Step Action Continue to hold the line up and select the HIGH FLOW TEST button. Wait for the flow from the Nozzle to stop. Repeat Step 3 10 times. This purges the Sanitizer from the HFCS line. Remove the Flush Adapter and connect a BiB of HFCS to the green BiB Connector.
Chapter 7: Water Circuit Cleaning Chapter Water Circuit Cleaning CLEANING OF THE COCA-COLA FREESTYLE® 7000 DISPENSER FOLLOWING A BOIL WATER ADVISORY Equipment Required Ensure you have the following equipment before beginning Water Circuit Cleaning. Kay 5 Sanitizer, 2 1-oz packets (Coca-...
Chapter 7: Water Circuit Cleaning Cleaning Procedure Prepare Sanitizer Step Action In a clean 5 gallon Bucket, prepare 5 gallons of Kay-5 Sanitizer (two 1oz packet of Kay- 5). Use hot water. Note: Do not exceed 100 ppm Sanitizer strength as this causes damage to the equipment.
Chapter 7: Water Circuit Cleaning III. Prepare the Water Circuit Depressurize and purge the water circuits. Step Action In the backroom, turn off the water supply to the dispenser. Remove the Splash Plate to the front of the dispenser (requires removal of two screws - one for plate, one for ground wire).
Chapter 7: Water Circuit Cleaning Step Action Insert the straight fitting end into the Cleaning Electric Pump outlet port, and the 90 degree fitting end into the dispenser pump inlet port. Secure both connections with the locking clip on these ports. Insert the straight fitting of the Water CIP Tubing Kit into the Sanitizer and then insert into the Cleaning Electric Pump inlet port and secure the locking clip on this port.
Page 48
Chapter 7: Water Circuit Cleaning Step Action Allow the Sanitizer to remain at rest in the water circuits and carbonator tank for 5 minutes. Classified – Confidential Page 43 of 46...
Chapter 7: Water Circuit Cleaning Flush the Sanitizer Flush Sanitizer from the water circuits and carbonation tank. Step Action From the Technician UI, select CARB WATER until nothing flows from the nozzle. From the Technician UI, select PLAIN WATER until nothing flows from the nozzle. Disconnect the Water CIP Tubing Kit from the Dispenser Electric Pump.
Chapter 7: Water Circuit Cleaning VII. Return the Dispenser to Service Restart the carbonator and return the dispenser to service. Step Action From the Technician Dashboard, Re-Initialize the Macro Module. Note: After completing re-initialization, the Carb Motor turns on until it refills the carb tank with water.