Chapter 7: Water Circuit Cleaning
VI.

Flush the Sanitizer

Flush Sanitizer from the water circuits and carbonation tank.
Step
From the Technician UI, select CARB WATER until nothing flows from the nozzle.
1.
From the Technician UI, select PLAIN WATER until nothing flows from the nozzle.
2.
Disconnect the Water CIP Tubing Kit from the Dispenser Electric Pump.
3.
Reconnect the dispenser incoming water line to the inlet of the Dispenser Electric Pump.
4.
In the backroom, open the water supply to the dispenser.
5.
From the Technician UI, select CARB WATER and flow for a minimum of three minutes.
This allows supply water to flush the sanitizing solution from the Carb Water circuit.
6.
This may require multiple separate presses due to timeout.
In the backroom, open the CO2 Shutoff valve.
7.
From the Technician UI, select CARB WATER and flow until only CO2 blows from the
8.
nozzle. This may require multiple separate presses due to timeout.
From the Technician UI, select PLAIN WATER and flow for a minimum of one minute.
This allow supply water to flush the sanitizing solution from the Plain Water circuit. This
9.
may require multiple separate presses due to timeout.