I. Coca-Cola Freestyle - 8100 Self-Serve Dispenser A. Agitation Troubleshooting Agitation Troubleshooting Steps Possible Component Component Step Component Results Failure/ Inspection/Test Observation 1. When leveling the dispenser, a) Component passed inspection/test? lifting the dispenser with either the Yes, move to step 2.
Page 4
Agitation Troubleshooting Steps Possible Component Component Step Component Results Failure/ Inspection/Test Observation a) Component passed inspection/test? Visual Inspection Yes, move to step 5. 1. Verify hinge brackets are tight for b) Component failed inspection/test? Door(s) not closing/ Door(s) both the upper and lower doors. latching properly •...
Page 5
Agitation Troubleshooting Steps Possible Component Component Step Component Results Failure/ Inspection/Test Observation 1. Check agitation electrical harness a) Component passed inspection/test? connectors are fully seated and Yes, move to step 11. making good contact. b) Component failed inspection/test? Agitation No power 2.
B. HFCS Troubleshooting HFCS Troubleshooting Steps Possible Component Component Step Component Results Failure/ Inspection/Test Observation a) Component passed inspection/test? Yes, move to step 2. Correct Slanted Syrup Rack Visually Inspect Syrup Rack b) Component failed inspection/test? • Replace with correct Syrup Rack a) Component passed inspection/test? Yes, move to step 3.
Page 7
HFCS Troubleshooting Steps Possible Component Component Step Component Results Failure/ Inspection/Test Observation 1. Check for kinked tubing coming a) Component passed inspection/test? into the vacuum regulator. Yes, move to step 9. 2. Verify vaccuum regulator is b) Component failed inspection/test? Vacuum NO flow from connected and flowing in the...
Page 8
HFCS Troubleshooting Steps Possible Component Component Step Component Results Failure/ Inspection/Test Observation a) Component passed inspection/test? 1. Visually inspect for cracks or Yes, move to step 10.1. damage. b) Component failed inspection/test? Leaking air vent 2. Verify correct check valve in outlet port (Red dot in middle of check •...
Page 9
HFCS Troubleshooting Steps Possible Component Component Step Component Results Failure/ Inspection/Test Observation 1. Remove solenoid from back block. a) Component passed inspection/test? 2. Disconnect HFCS inlet on bottom • Go back to HFCS troubleshooting step 11. of internal cold plate. b) Component failed inspection/test? 3.
D. NNS Troubleshooting NNS Troubleshooting Steps Possible Component Component Step Component Results Failure/ Inspection/Test Observation a) Component passed inspection/test? Yes, move to step 2. Bag in Box Empty Package Visually Inspect b) Component failed inspection/test? • Replace and prime. a) Component passed inspection/test? Yes, move to step 3.
Page 12
NNS Troubleshooting Steps Possible Component Component Step Component Results Failure/ Inspection/Test Observation 1. Remove NNS tray to access a) Component passed inspection/test? SPM(s). Yes, move to step 7. 2. Perform "Hold To Pour" Test b) Component failed inspection/test? i. Log in as a tech (2653) 1.
Page 13
NNS Troubleshooting Steps Possible Component Component Step Component Results Failure/ Inspection/Test Observation 1. Perform "Hold To Pour" Test a) Component failed inspection/test? i. Log in as a tech (2653) • Replace Nozzle Assembly. ii. Select the NNS Icon on the dashboard.
E. Soda Water/Carbonation Troubleshooting Soda Water Troubleshooting Steps Possible Component Component Step Component Results Failure/ Inspection/Test Observation a) Component passed inspection/test? Yes, move to step 1.1. No water at Is the water turned off at the source? source/supply b) Component failed inspection/test? •...
Page 15
Yes, move to step 6.1. Broken/Defective Visual Inspection b) Component failed inspection/test? CO2 Gauges • Repair or replace broken/defective gauges. (Coca-Cola a) Component passed inspection/test? equipment) Use an air pressure gauge to verify Yes, move to step 7. Incorrect settings pressures are set correctly.
Page 16
Soda Water Troubleshooting Steps Possible Component Component Step Component Results Failure/ Inspection/Test Observation a) Component passed inspection/test? CO2 Shut-off Visual Inspection Yes, move to step 13. No flow/ (Brass inside (Verify CO2 Shut-Off is in the ON Restricted flow b) Component failed inspection/test? dispenser) position) •...
Page 17
Soda Water Troubleshooting Steps Possible Component Component Step Component Results Failure/ Inspection/Test Observation 1. Verify carbonator is enabled on carb a) Component passed inspection/test? water screen. Yes, move to step 17. 2. Visually inspect if the 110VAC b) Component failed inspection/test? breaker is tripped on the 110VAC •...
Page 18
Soda Water Troubleshooting Steps Possible Component Component Step Component Results Failure/ Inspection/Test Observation High 200 +/- 10% a) Component passed inspection/test? Check soda water (180 - 220) Yes, move to step 23. Water check No/Restricted Water flow rates 3X b) Component failed inspection/test? valve flow alternating into...
F. Cartridge Troubleshooting Cartridge not reading on Dashboard Possible Component Component Step Component Results Failure/ Inspection/Test Observation a) Component passed inspection/test? Yes, move to step 2. 1. Visual Inspection RFID Tag on RFID Tag not Cartridge reading b) Component failed inspection/test? 2.
Page 20
Cartridge not reading on Dashboard Possible Component Component Step Component Results Failure/ Inspection/Test Observation a) Component passed inspection/test? Yes, move to step 6. Pump Board Visual inspection No power Harness (Broken/Frayed Harness) b) Component failed inspection/test? • Replace Pump Board Harness. a) Component passed inspection/test? Yes, move to step 7.
G. Water Troubleshooting Water Troubleshooting Steps Possible Component Component Step Component Results Failure/ Inspection/Test Observation a) Component passed inspection/test? Yes, move to step 1.1. No water at Is the water turned off at the source? source/supply b) Component failed inspection/test? •...
Page 22
Water Troubleshooting Steps Possible Component Component Step Component Results Failure/ Inspection/Test Observation a) Component passed inspection/test? Yes, move to step 7. Water No flow from water Remove and visually inspect for water regulator regulator flow b) Component failed inspection/test? • Replace water regulator with (60PSIG). 1.
Page 23
Water Troubleshooting Steps Possible Component Component Step Component Results Failure/ Inspection/Test Observation a) Component passed inspection/test? Yes, move to step 11. Low/NO flow from Visually inspect for restricted Water b) Component failed inspection/test? Water Tubing Water Tubing. Tubing. • Remove restriction •...
H. APC Troubleshooting APC Troubleshooting Steps Possible Component Component Step Component Results Failure/ Inspection/Test Observation a) Component passed inspection/test? Yes, move to step 1.1. APC Scale not Verify APC scale turned on in software displayed on screen b) Component failed inspection/test? •...
I. Network Connectivity Troubleshooting Network Connectivity Troubleshooting Steps Step Icon Name LED Observation Results Solid "Green" Power on, continue to step 2. Power off: • Verify green power connector is securely connected to modem "Off" Power power supply and that the other end is securely connected to the HMI board.