Huawei SmartModule1000A01 Quick Manual page 9

Table of Contents

Advertisement

4.6
Connecting the DI Signal Cable
The SmartModule can receive DI signals such as remote power grid scheduling commands and
alarms over DI ports. It can only receive passive dry contact signals.
It is recommended that the signal transmission distance be less than or equal to 10 m.
4.7
Connecting the Output Power Cable
In the grid connection with limited power or audible and visual alarm scenarios, the
SmartModule can drive the coils of the intermediate relay over the 12 V output power port.
It is recommended that the transmission distance be less than or equal to 10 m.
Port
DI1
DI2
DI3
DI4
Intermediate relay
8
Description
Can receive passive
dry contact signals.