453. Fertiliser tramlining LH and
RH
461. BioDrill tramlining LH
462. BioDrill tramlining RH
463. BioDrill tramlining LH and RH
470. CAN BUS error
520. Interrupted connection with
Gateway
No contact between iPad and
Gateway
760. Low speed, seed
770. Low speed, fertiliser
780. Low speed, BioDrill
790. Technical error, radar
Speed = 0
Speed > 7.0 km/h less than 0.7
seconds
1080 Lost contact with Universal
Control
1090 AutoPilot, maximum drilling
depth
903099-en-gb; 19.01.2021
See alarm no. 451
Check the sensor's cable, contacts and connections.
Check the sensor.
Check the sensor's cable, contacts and connections.
Check the sensor.
Check the sensor's cable, contacts and connections.
Check the sensor.
Check the CAN's wiring, connectors and connections.
Check that the cable is not trapped or otherwise damaged. Check the condition
of the connectors.
Check the cabling between Gateway and the terminal
The hydraulic motor is sitting at the lower limit for permitted speed
Check the oil flow rate
Check the calibration
Check the roller
The hydraulic motor is sitting at the lower limit for permitted speed
Check the oil flow rate
Check the calibration
Check the roller
The hydraulic motor is sitting at the lower limit for permitted speed
Check the oil flow rate
Check the calibration
Check the roller
Check the sensor's cable, contacts and connections.
Check the sensor.
System has lost contact with external application
Make sure that the external application is in contact with Universal Control.
AutoPilot has reached the maximum permitted drilling depth. Check the
position of the sensor.
Alarm list