DeDietrich HPI S User Manual page 16

Reversible air/water "split inverter" heat pump
Table of Contents

Advertisement

3 Technical specifications
Product name
Electrical power consumption
Off mode
Thermostat-off mode
Stand-by
Crankcase heater mode
Supplementary heater
Rated heat output
Type of energy input
Other specifications
Capacity control
Sound power level, indoors - outdoors
Annual energy consumption under average conditions
Annual energy consumption under colder conditions
Annual energy consumption under warmer conditions
Rated air flow rate, outdoors for air-to-water heat pumps
(1) The rated heat output
Psup is equal to the supplementary capacity for heating sup(Tj) .
Cdh is not determined by measurement, the default degradation coefficient is Cdh = 0.9.
(2) If
Tab.12
Technical parameters for heat pump combination heaters (parameters declared for medium-temperature application)
Product name
Air-to-water heat pump
Water-to-water heat pump
Brine-to-water heat pump
Low-temperature heat pump
Equipped with a supplementary heater
Heat pump combination heater
Rated heat output under average conditions
Rated heat output under colder conditions
Rated heat output under warmer conditions
Declared capacity for heating for part load at an indoor temperature of
20 °C and outdoor temperature
T
= -7 °C
j
T
= +2 °C
j
T
= +7 °C
j
T
= +12 °C
j
T
= bivalent temperature
j
T
= operation limit temperature
j
Bivalent temperature
Degradation coefficient
Seasonal space heating energy efficiency under average conditions
Seasonal space heating energy efficiency under colder conditions
Seasonal space heating energy efficiency under warmer conditions
Declared coefficient of performance or primary energy ratio for part
load at an indoor temperature of 20 °C and outdoor temperature
T
= -7 °C
j
T
= +2 °C
j
T
= +7 °C
j
T
= +12 °C
j
16
MIT-S
Prated is equal to the design load for heating Pdesignh , and the rated heat output of a supplementary heater
(1)
T
j
(2)
P
kW
OFF
P
kW
TO
P
kW
SB
P
kW
CK
Psup
kW
L
dB
WA
Q
kWh
HE
Q
kWh
HE
Q
kWh
HE
3
m
/h
Prated
kW
Prated
kW
Prated
kW
Pdh
kW
Pdh
kW
Pdh
kW
Pdh
kW
Pdh
kW
Pdh
kW
T
°C
biv
Cdh
ƞ
%
s
ƞ
%
s
ƞ
%
s
T
j
COPd
-
COPd
-
COPd
-
COPd
-
AWHP 11 MR-2
AWHP 16 MR-2
AWHP 11 TR-2
AWHP 16 TR-2
0.009
0.009
0.049
0.035
0.021
0.021
0.055
0.055
0.0
0.0
Electricity
Electricity
Variable
Variable
51 - 69
51 - 69
3999
5861
3804
5684
2580
4120
6000
6000
AWHP 22 TR–2 AWHP 27 TR–2
Yes
Yes
No
No
No
No
No
No
Yes
Yes
No
No
11
14
12
14
18
20
10.3
12.4
10.0
8.9
5.8
11.8
6.9
18.1
10.9
12.4
10.9
14.1
-10
-7
1.0
1.0
114
112
111
103
143
141
1.95
1.67
2.80
2.86
3.76
4.12
4.85
5.06
7684505 - v03 - 14052020

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents